Atrial Linear Lesions: Feasibility Using Cryoablation
- 21 March 2006
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 29 (3) , 283-289
- https://doi.org/10.1111/j.1540-8159.2006.00335.x
Abstract
Background: Long linear lesions are created in the left atrium to modify the atrial substrate, thereby curing atrial fibrillation. The creation of long linear left atrial lesions using radiofrequency (RF) ablation is time consuming and difficult. Furthermore, it might result in significant complications. Cryoablation might overcome some of the disadvantages of RF ablation. Therefore, the aim of our study was to assess whether the creation of a long linear lesion is possible using cryotherapy. Methods: A right atrial septal linear lesion was created in six pigs (median weight: 50 kg; range: 40–60 kg). The ablation procedure was performed with a 7‐F Freezor cryocatheter. The nonfluoroscopic mapping system LocaLisa was used as a navigation tool. At each point, freezing was maintained at the lowest attainable temperature (−75°C) for 4 minutes. The CARTO system was used for the evaluation of the linear lesions. Furthermore, all animals were sacrificed immediately after the ablation procedure and a postmortem examination of the lesions was performed. Additionally, an analysis of the amplitudes of the intracardiac electrograms registered via the ablation catheter was performed before and after the ablation procedure. Results: A right atrial septal linear lesion could be created successfully in all six pigs. For the performance of this ablation line, a median number of 16 cryoapplications (range, 11–26) was necessary. The amplitudes of the intracardiac electrograms registered via the ablation catheter decreased significantly after ablation. The CARTO bipolar voltage map revealed very low potentials along the ablation line and showed a sharply demarcated ablation area at the septum in all pigs. Further analysis of the CARTO map revealed an incomplete conduction block in all cases. Most of the pigs had a small gap close to the fossa ovalis. The postmortem examination of 2,3,5‐triphenyl‐tetrazolium chloride‐stained specimens showed sharply demarcated lesions without any ulcerations. There were no major complications during the procedure. Conclusions: The creation of long linear lesions using cryoablation is feasible and safe. Lesion characteristics are different and more favorable than those created by RF. However, the aim of creating a transmural lesion and a complete conduction block remains an unsolved problem even with current cryoablation techniques. Nevertheless, growing experience and technical improvements might overcome some of the current limitations of this new technique.Keywords
This publication has 34 references indexed in Scilit:
- Incidence and Prevention of Cardiac Tamponade Complicating Ablation for Atrial FibrillationPacing and Clinical Electrophysiology, 2005
- Linear Cryoablation of the Left Atrium Versus Pulmonary Vein Cryoisolation in Patients With Permanent Atrial Fibrillation and Valvular Heart DiseaseCirculation, 2005
- Technique and Results of Linear Ablation at the Mitral IsthmusCirculation, 2004
- Noninducibility of Atrial Fibrillation as an End Point of Left Atrial Circumferential Ablation for Paroxysmal Atrial FibrillationCirculation, 2004
- Changes in Atrial Fibrillation Cycle Length and Inducibility During Catheter Ablation and Their Relation to OutcomeCirculation, 2004
- Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial FibrillationCirculation, 2004
- LocaLisa Catheter Navigation Reduces Fluoroscopy Time and Dosage in Ablation of Atrial Flutter:Journal of Cardiovascular Electrophysiology, 2003
- Segmental Ostial Ablation to Isolate the Pulmonary Veins During Atrial FibrillationCirculation, 2002
- Mapping-guided ablation of pulmonary veins to cure atrial fibrillationThe American Journal of Cardiology, 2000
- Transvenous Cold Mapping and Cryoablation of the AV Node in Dogs: Observations of Chronic Lesions and Comparison to Those Obtained Using Radiofrequency AblationJournal of Cardiovascular Electrophysiology, 1998