Application of distance-dependent resolution compensation and post-reconstruction filtering for myocardial SPECT
- 1 June 1998
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 43 (6) , 1679-1693
- https://doi.org/10.1088/0031-9155/43/6/022
Abstract
Compensation for distance-dependent resolution can be directly incorporated in maximum likelihood reconstruction. Our objective was to examine the effectiveness of this compensation using either the standard expectation maximization (EM) algorithm or an accelerated algorithm based on use of ordered subsets (OSEM). We also investigated the application of post-reconstruction filtering in combination with resolution compensation. Using the MCAT phantom, projections were simulated for data, including attenuation and distance-dependent resolution. Projection data were reconstructed using conventional EM and OSEM with subset size 2 and 4, with/without 3D compensation for detector response (CDR). Also post-reconstruction filtering (PRF) was performed using a 3D Butterworth filter of order 5 with various cutoff frequencies (0.2-). Image quality and reconstruction accuracy were improved when CDR was included. Image noise was lower with CDR for a given iteration number. PRF with cutoff frequency greater than improved noise with no reduction in recovery coefficient for myocardium but the effect was less when CDR was incorporated in the reconstruction. CDR alone provided better results than use of PRF without CDR. Results suggest that using CDR without PRF, and stopping at a small number of iterations, may provide sufficiently good results for myocardial SPECT. Similar behaviour was demonstrated for OSEM.Keywords
This publication has 13 references indexed in Scilit:
- Reducing the influence of the partial volume effect on SPECT activity quantitation with 3D modelling of spatial resolution in iterative reconstructionPhysics in Medicine & Biology, 1998
- Influence of OSEM, elliptical orbits and background activity on SPECT 3D resolution recoveryPhysics in Medicine & Biology, 1997
- A clinical perspective of accelerated statistical reconstructionEuropean Journal of Nuclear Medicine and Molecular Imaging, 1997
- Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensationIEEE Transactions on Medical Imaging, 1996
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- The convergence of object dependent resolution in maximum likelihood based tomographic image reconstructionPhysics in Medicine & Biology, 1993
- A fast Bayesian reconstruction algorithm for emission tomography with entropy prior converging to feasible imagesIEEE Transactions on Medical Imaging, 1990
- An evaluation of maximum likelihood reconstruction for SPECTIEEE Transactions on Medical Imaging, 1990
- Bayesian reconstructions from emission tomography data using a modified EM algorithmIEEE Transactions on Medical Imaging, 1990
- A Maximum a Posteriori Probability Expectation Maximization Algorithm for Image Reconstruction in Emission TomographyIEEE Transactions on Medical Imaging, 1987