Carbohydrate Chromatography: Towards Yoctomole Sensitivity
- 1 November 1996
- journal article
- review article
- Published by Wiley in Biomedical Chromatography
- Vol. 10 (6) , 285-289
- https://doi.org/10.1002/(sici)1099-0801(199611)10:6<285::aid-bmc616>3.0.co;2-w
Abstract
In attempting to analyse complex carbohydrates by HPLC or capillary electrophoresis (CE) the chromatographer is faced with many challenges. The diversity of oligosaccharide structures described the date and their poor resolution on many chromatographic systems present a significant challenge to the chromatographer. In addition to this, the non-chromogenic nature of most carbohydrates greatly decreases the sensitivity of UV detection and refractive index is not an option for sensitive analysis. Over the last five years there have been significant advances in separation and detection methods for carbohydrates, and in this paper we will attempt to describe the most significant advances and highlight potential future developments. The detection of 200-300 fmol (2-3 x 10(-3) mol) of oligosaccharides can now be readily achieved using electrochemical detection or fluorescence detection (after labelling) with conventional HPLC columns and detectors. Miniaturized separation systems have greatly increased sensitivities with a CE-laser induced fluorescence instrument detecting as little as 100 yoctomoles (1 x 10(-22) mol).Keywords
This publication has 40 references indexed in Scilit:
- Characterization of protein glycosylation by mass spectrometryCurrent Opinion in Biotechnology, 1996
- Recent progress in carbohydrate separation by high-performance liquid chromatography based on size exclusionJournal of Chromatography A, 1996
- Analysis of Mono- and Oligosaccharide Isomers Derivatized with 9-Aminopyrene-1,4,6-trisulfonate by Capillary Electrophoresis with Laser-Induced FluorescenceAnalytical Biochemistry, 1995
- Nonselective and Efficient Fluorescent Labeling of Glycans Using 2-Amino Benzamide and Anthranilic AcidAnalytical Biochemistry, 1995
- Skeletal keratan sulphate structural analysis using keratanase II digestion followed by high-performance anion-exchange chromatographyGlycobiology, 1995
- Yoctomole detection limit by laser-induced fluorescence in capillary electrophoresisJournal of Chromatography B: Biomedical Sciences and Applications, 1994
- Molecular size analysis of capsular polysaccharide preparations from Streptococcus pneumoniaeCarbohydrate Research, 1993
- Characterization of chitosans via coupled size-exclusion chromatography and multiple-angle laser light-scattering techniqueCarbohydrate Research, 1993
- On-column laser-based refractive index detector for capillary electrophoresisAnalytical Chemistry, 1991
- Subnanoliter laser-based refractive index detector for 0.25-mm I.D. microbore liquid chromatography: Reversed-phase separation of nanogram amounts of sugarsJournal of Chromatography A, 1987