Abstract
A number of parameters that influence sludge dewatering behaviour have been identified, but there is a lack of consensus which of these are of the greatest concern in sludge treatment strategies. Moisture retention characteristics were obtained from vacuum drying of centrifuged sludge samples to subdivide moisture into immobilised, physically and chemically bound fractions. Physically bound moisture is responsible for unsatisfactory dewatering by centrifugation. Polyelectrolyte releases some of the immobilised water, but simultaneously increases the physically bound moisture content which gives rise to large energy inputs during mechanical dewatering. Commonly used dewaterability measurements do not appear to be linked to moisture retention characteristics.

This publication has 0 references indexed in Scilit: