Calculated Pulse Widths and Spectra of a Single Sonoluminescing Bubble
- 30 May 1997
- journal article
- other
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 276 (5317) , 1398-1401
- https://doi.org/10.1126/science.276.5317.1398
Abstract
A sonoluminescing bubble has been modeled as a thermally conducting, partially ionized, two-component plasma. The model shows that the measured picosecond pulse widths are due to electron conduction and the rapidly changing opacity of the plasma and that these mechanisms are also responsible for the absence of an “afterglow” subsequent to the sonoluminescence flash while the hot bubble expands and cools. The calculated spectra for sonoluminescing nitrogen and argon bubbles suggest that a sonoluminescing air bubble probably contains only argon, in agreement with a recent theoretical analysis.Keywords
This publication has 16 references indexed in Scilit:
- Sonoluminescing Air Bubbles Rectify ArgonPhysical Review Letters, 1997
- Understanding the periodic driving pressure in the Rayleigh–Plesset equationThe Journal of the Acoustical Society of America, 1997
- Observation of a New Phase of Sonoluminescence at Low Partial PressuresPhysical Review Letters, 1995
- Effect of Noble Gas Doping in Single-Bubble SonoluminescenceScience, 1994
- Sensitivity of sonoluminescence to experimental parametersPhysical Review Letters, 1994
- Shock-wave propagation in a sonoluminescing gas bubblePhysical Review Letters, 1993
- Spectrum of synchronous picosecond sonoluminescencePhysical Review Letters, 1992
- Sonoluminescence and bubble dynamics for a single, stable, cavitation bubbleThe Journal of the Acoustical Society of America, 1992
- Observation of synchronous picosecond sonoluminescenceNature, 1991
- Equation of state of dense, partially degenerate, reacting plasmasPhysical Review A, 1981