Subfemtomole MS and MS/MS Peptide Sequence Analysis Using Nano-HPLC Micro-ESI Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
- 12 August 2000
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 72 (18) , 4266-4274
- https://doi.org/10.1021/ac000497v
Abstract
Subfemtomole peptide sequence analysis has been achieved using microcapillary HPLC columns, with integrated nanoelectrospray emitters, coupled directly to a Fourier transform ion cyclotron resonance mass spectrometer. Accurate mass (±0.010 Da) peptide maps are generated from a standard six-protein digest mixture, whose principle components span a concentration dynamic range of 1000:1. Iterative searches against ∼189 000 entries in the OWL database readily identify each protein, with high sequence coverage (20−60%), from as little as 10 amol loaded on-column. In addition, a simple variable-flow HPLC apparatus provides for on-line tandem mass spectrometric analysis of tryptic peptides at the 400-amol level. MS/MS data are searched against ∼280 000 entries in a nonredundant protein database using SEQUEST. Accurate precursor and product ion mass information readily identifies primary amino acid sequences differing by asparagine vs aspartic acid (Δm = 0.98 Da) and glutamine vs lysine (Δm = 0.036 Da).This publication has 56 references indexed in Scilit:
- Matrix-assisted ultraviolet laser desorption of non-volatile compoundsPublished by Elsevier ,2001
- Efficient sequence analysis of the six gene products (7‐74 kDA) from the escherichia coli thiamin biosynthetic operon by tandem high‐resolution mass spectrometryProtein Science, 1998
- High Sensitivity Collisionally-activated Decomposition Tandem Mass Spectrometry on a Novel Quadrupole/Orthogonal-acceleration Time-of-flight Mass SpectrometerRapid Communications in Mass Spectrometry, 1996
- X-ray spectrometryAnalytical Chemistry, 1992
- Structural analysis of proteins by capillary HPLC electrospray tandem mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1991
- Fused silica packed microcolumns as micropreparative tools in protein analytical studiesAnalytical Chemistry, 1988
- Long range effects of the aluminum avoidance principleAnalytical Chemistry, 1985
- Coupling a quadrupole mass spectrometer and a Fourier transform mass spectrometerInternational Journal of Mass Spectrometry and Ion Processes, 1985
- Hollow fiber post-column reactor for liquid chromatographyAnalytical Chemistry, 1985
- Pulsed free jets: novel nonlinear media for generation of vacuum ultraviolet and extreme ultraviolet radiationThe Journal of Physical Chemistry, 1984