Severe aseptic synovitis of the knee after biodegradable internal fixation
- 1 January 1992
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 63 (1) , 94-97
- https://doi.org/10.3109/17453679209154859
Abstract
Biodegradable rods made of polyglycolide (Dexon ®, Biofix ®) or lactide-glycolide copolymer (Vicryl ®) have been used for the past 5 years for internal fixation of a variety of fractures and osteotomies (Böstman et al. 1989, 1990b). Experience from using such rods for fixation of intraarticular osteochondral lesions seems to be less extensive. We report a case of severe synovial reaction to biodegradable rods used for fixation of osteochondritis dissecans of the knee and discuss possible reasons for the increased risk of foreign-body reactions when these rods are used intraarticularly.Keywords
This publication has 8 references indexed in Scilit:
- Immune response to polyglycolic acid implantsThe Journal of Bone and Joint Surgery. British volume, 1990
- Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymersThe Journal of Bone and Joint Surgery. British volume, 1990
- Degradable polyglycolide rods for the internal fixation of displaced bimalleolar fracturesInternational Orthopaedics, 1990
- Ankle Fractures Treated Using Biodegradable Internal FixationClinical Orthopaedics and Related Research, 1989
- Biodegradable internal fixation for malleolar fractures. A prospective randomised trialThe Journal of Bone and Joint Surgery. British volume, 1987
- C1 Activation, with C1q in Excess of Functional C1 in Synovial Fluid from Patients with Rheumatoid ArthritisInternational Archives of Allergy and Immunology, 1986