Biomechanics of Transfixation in Pedicle Screw Instrumentation
- 1 October 1996
- journal article
- Published by Wolters Kluwer Health in Spine
- Vol. 21 (19) , 2224-2229
- https://doi.org/10.1097/00007632-199610010-00009
Abstract
The biomechanical role of transfixation in pedicle screw instrumentation was investigated using flexibility tests and finite element analyses. To assess the stabilizing effect of use and position of transfixators. Transfixation is common in pedicle screw instrumentation, however, its biomechanical role and optimal position are not completely understood. Specimens underwent nondestructive flexibility tests using a three-dimensional motion analysis system. Tests compared the intact spine with instrumentation with and without transfixators Rotational angles of the superior vertebra, resulting from the maximum moment of 6.4 Nm, were compared. Three-dimensional finite element models investigated transfixator position. Rotations of the superior vertebra were compared for cases with and without transfixators to determine the position providing the greatest stability. Biomechanical test showed that only axial rotational stability significantly improved with transfixators compared with instrumentation alone. Pimte element models predicted improvement in lateral bending and axial rotation with transfixators compared with the case with no transfixator. With one transfixator, the greatest improvement in axial rotation stability occurred with the transfixator at the proximal 1/4 position of the rods. When two transfixators were used, the optimal locations were with one transfixator in the middle and the second at the proximal 1/8 position. Transfixators improved the stabilizing effects of pedicle screw instrumentation. The greatest axial rotation stability was obtained with two transfixators; one in the middle and the other at the proximal 1/8 position of the longitudinal rods.Keywords
This publication has 27 references indexed in Scilit:
- Longitudinal Element Size Effect on Load Sharing, Internal Loads, and Fatigue Life of Tri-Level Spinal Implant ConstructsSpine, 1993
- Mechanical Stability of the Pedicle Screw Fixation Systems for the Lumbar SpineSpine, 1992
- In Vitro Comparative Biomechanical Analysis of Transpedicular Screw Instrumentations in the Lumbar Region of the Human SpinePublished by Wolters Kluwer Health ,1991
- Experimental Evaluation of Seven Different Spinal Fracture Internal Fixation Devices Using Nonfailure Stability TestingSpine, 1991
- Importance of Bone Mineral Density in Instrumented Spine FusionsSpine, 1991
- A Biomechanical Investigation of Short Segment Spinal Fixation for Burst Fractures with Varying Degrees of Posterior DisruptionSpine, 1990
- An Analytical Investigation of the Mechanics of Spinal InstrumentationSpine, 1988
- A Technique to Evaluate an Internal Spinal Device by Use of the Selspot System: An Application to Luque Closed LoopSpine, 1987
- A Biomechanical Study of Intrapeduncular Screw Fixation in the Lumbosacral SpineClinical Orthopaedics and Related Research, 1986
- An Internal Fixator for Posterior Application to Short Segments of the Thoracic, Lumbar, or Lumbosacral Spine Design and TestingPublished by Wolters Kluwer Health ,1986