The applicability of evacuated serological tubes for the collection of breath for isotopic analysis of CO2 by isotope ratio mass spectrometry
- 1 May 1988
- journal article
- research article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 15 (9) , 467-472
- https://doi.org/10.1002/bms.1200150902
Abstract
Stable isotope ratio mass spectrometry was used for the analysis of 13C and 18O in CO2 of human breath collected in evacuated serological tubes (Vacutainer® and Venoject®) and in gas sample bottles. There was a 1–2‰0 difference between the δ13CPDB values obtained from breath CO2 collected in gas bottles and that collected in two batches of Vacutainer. δ18OPDB differed between Vacutainers and gas bottles by as much as 14%0 and standard deviations within the two batches of Vacutainer were 0.7 and 1.8%0. The poor reproducibility and accuracy for the δ18OPDB values was caused by the presence of a contaminant which originated from the rubber septa of the Vacutainers. The results show that it is not possible to obtain δ18OPDB values with a high degree of accuracy or precision for breath samples collected in Vacutainers. However, with selection of less contaminated or re‐evacuated batches, δ13CPDB analysis of breath CO2 in Vacutainers may provide acceptable accuracy and precision. δ13CPDB and δ18OPDB values measured in breath collected in non‐sterile Venoject tubes were also significantly different from those obtained with gas bottles. However, the accuracy and precision of these determinations were considerably better than in sterilized Vacutainer tubes. As a result of these comparisons it is concluded that gas bottles are necessary for the full accuracy and precision of stable isotope ratio analysis mass spectrometers to be exploited in breath CO2 analysis. However, automated analysis of breath CO2 collected in non‐sterile Venoject tubes will provide an accuracy and precision that is suitable for most biological studies.This publication has 14 references indexed in Scilit:
- A rapid analytical technique for the determination of energy expenditure by the doubly labelled water methodJournal of Mass Spectrometry, 1985
- Preparation of CO2 from blood and protein-bound amino acid carboxyl groups for quantification and13C-isotope measurementsJournal of Mass Spectrometry, 1984
- Effects of Duchenne muscular dystrophy on muscle protein synthesisNature, 1982
- Total body water measurement in humans with 18O and 2H labeled waterThe American Journal of Clinical Nutrition, 1980
- A microprocessor controlled mass spectrometer for the fully automated purification and isotopic analysis of breath carbon dioxideJournal of Mass Spectrometry, 1979
- A simplified technique for collecting breath CO2 for isotope ratio mass spectrometryJournal of Mass Spectrometry, 1978
- Sealed Tube Combustions for Determination of Carbon- 14 and Total CarbonAnalytical Chemistry, 1959
- Isotopic standards for carbon and oxygen and correction factors for mass-spectrometric analysis of carbon dioxideGeochimica et Cosmochimica Acta, 1957
- A method for the determination of the O18 concentration of the oxygen of organic compoundsThe International Journal of Applied Radiation and Isotopes, 1956