Fitting Characteristics of Eighteen N95 Filtering-Facepiece Respirators
- 1 April 2004
- journal article
- research article
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 1 (4) , 262-271
- https://doi.org/10.1080/15459620490433799
Abstract
Four performance measures were used to evaluate the fitting characteristics of 18 models of N95 filtering-facepiece respirators: (1) the 5th percentile simulated workplace protection factor (SWPF) value, (2) the shift average SWPF value, (3) the h-value, and (4) the assignment error. The effect of fit-testing on the level of protection provided by the respirators was also evaluated. The respirators were tested on a panel of 25 subjects with various face sizes. Simulated workplace protection factor values, determined from six total penetration (face-seal leakage plus filter penetration) tests with re-donning between each test, were used to indicate respirator performance. Five fit-tests were used: Bitrex™, saccharin, generated aerosol corrected for filter penetration, PortaCount® Plus corrected for filter penetration, and the PortaCount Plus with the N95-Companion™ accessory. Without fit-testing, the 5th percentile SWPF for all models combined was 2.9 with individual model values ranging from 1.3 to 48.0. Passing a fit-test generally resulted in an increase in protection. In addition, the h-value of each respirator was computed. The h-value has been determined to be the population fraction of individuals who will obtain an adequate level of protection (i.e., SWPF ≥ 10, which is the expected level of protection for half-facepiece respirators) when a respirator is selected and donned (including a user seal check) in accordance with the manufacturer's instructions without fit-testing. The h-value for all models combined was 0.74 (i.e., 74% of all donnings resulted in an adequate level of protection), with individual model h-values ranging from 0.31 to 0.99. Only three models had h-values above 0.95. Higher SWPF values were achieved by excluding SWPF values determined for test subject/respirator combinations that failed a fit-test. The improvement was greatest for respirator models with lower h-values. Using the concepts of shift average and assignment error to measure respirator performance yielded similar results. The highest level of protection was provided by passing a fit-test with a respirator having good fitting characteristics.Keywords
This publication has 7 references indexed in Scilit:
- Comparison of Five Methods for Fit-Testing N95 Filtering-Facepiece RespiratorsApplied Occupational and Environmental Hygiene, 2002
- Respiratory protection as a function of respirator fitting characteristics and fit-test accuracy.Aihaj Journal, 2001
- Capability of Respirator Wearers to Detect Aerosolized Qualitative Fit Test Agents (Sweetener and Bitrex) with Known Fixed LeaksApplied Occupational and Environmental Hygiene, 2000
- Simulated Workplace Performance of N95 RespiratorsAihaj Journal, 1999
- Comparison of Six Respirator Fit-Test Methods with an Actual Measurement of Exposure in a Simulated Health Care Environment: Part II — Method Comparison TestingAihaj Journal, 1998
- ASSIGNED PROTECTION FACTORS FOR TWO RESPIRATOR TYPES BASED UPON WORKPLACE PERFORMANCE TESTINGAnnals of Occupational Hygiene, 1984