Effect of body mass index (BMI) on estimation of extracellular volume (ECV) in hemodialysis (HD) patients using segmental and whole body bioimpedance analysis
- 30 March 2005
- journal article
- clinical trial
- Published by IOP Publishing in Physiological Measurement
- Vol. 26 (2) , S93-S99
- https://doi.org/10.1088/0967-3334/26/2/009
Abstract
The aim of the study was to investigate whether body mass index (BMI) influences the estimation of extracellular volume (ECV) in hemodialysis (HD) patients when using segmental bioimpedance analysis (SBIA) compared to wrist-to-ankle bioimpedance analysis (WBIA) during HD with ultrafiltration (UF). Twenty five HD patients (M:F 19:6,) were studied, and further subdivided into two groups of patients, one group with a high BMI (25 kg m-2) and the other with a low BMI (<25 kg m-2). Segmental (arm, trunk, leg) and wrist-to-ankle bioimpedance measurements on each patient were performed using a modified Xitron 4000B system (Xitron Technologies, San Diego, CA). No differences in extracellular resistance (R(E), ohms) between wrist-to-ankle (R(W)) and sum of segments (R(S)) were noted for either the high BMI (489.2+/-82 ohm versus 491.6+/-82 ohm, p=ns) or low BMI groups (560.8+/-77 ohm versus 557.5+/-75 ohm, p=ns). UF volume (UFV, liters) did not differ significantly between the groups (4.0+/-0.9 L versus 3.3+/-1.0 L, p=ns), but change in ECV (DeltaECV) differed not only between methods: WBIA versus SBIA in the high BMI group (2.74+/-1.1 L versus 3.64+/-1.4 L, p<0.001) and in the low BMI group (1.86+/-0.9 L versus 2.91+/-1.0 L, p<0.05) but also between the high and lower BMI groups with WBIA (2.74+/-1.1 L versus 1.86+/-0.9 L, p<0.01). However, there was no significant difference in SBIA between BMI groups. This study suggests that the segmental bioimpedance approach may more accurately reflect changes in ECV during HD with UF than whole body impedance measurements.Keywords
This publication has 13 references indexed in Scilit:
- Body fat determination by dual energy X-ray absorptiometry and its relation to body mass index and waist circumference in Hong Kong ChineseInternational Journal of Obesity, 2001
- Sum of segmental bioimpedance analysis during ultrafiltration and hemodialysis reduces sensitivity to changes in body positionKidney International, 1999
- Validation of Changes in Extracellular Volume Measured During Hemodialysis Using a Segmental Bioimpedance TechniqueAsaio Journal, 1998
- Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysisJournal of Applied Physiology, 1998
- Does adipose tissue influence bioelectric impedance in obese men and women?Journal of Applied Physiology, 1998
- Predicting body cell mass with bioimpedance by using theoretical methods: a technological reviewJournal of Applied Physiology, 1997
- Effect of postural changes on the reliability of volume estimations from bioimpedance spectroscopy dataKidney International, 1997
- Body fluid determinations using multiple impedance measurementsIEEE Engineering in Medicine and Biology Magazine, 1989
- Principles of the impedance techniqueIEEE Engineering in Medicine and Biology Magazine, 1989
- Electrical measurement of fluid distribution in legs and armsPublished by Springer Nature ,1987