Observations on the Measurement of Vibrational Circular Dichroism with Rapid-Scan and Step-Scan FT-IR Techniques
- 1 September 1995
- journal article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 49 (9) , 1347-1355
- https://doi.org/10.1366/0003702953965245
Abstract
Extensive tests to determine an optimal method for using a Bio-Rad FTS-60A spectrometer for measurement of vibrational circular dichroism (VCD) in both step-scan and rapid-scan modes are reported. In the latter case, results of “fast-scan” and “slow-scan” experiments are also presented for comparison. In step-scan mode, phase modulation (PM) during the polarization-modulation measurements is found to be detrimental to the signal-to-noise ratio (S/N), but is very useful for the normal IR measurements at slow step speeds. VCD S/N is improved by doing sequential spectral collection of the polarization-modulated spectrum without PM and the instrument response spectra with phase modulation. Systematic comparative studies are used to identify optimal parameter sets for doing the step-scan VCD measurements. These conditions use more rapid data collection with faster steps than previously suggested, which permits a more realistic evaluation of S/N and reproducibility of the spectra through comparison of spectra collected in blocks. Example VCD spectra are presented for small molecules in nonaqueous solution measured in short times and for proteins in aqueous solution measured over longer times scales. Near-IR FT-VCD measured in step-scan mode at both moderate resolution and high S/N are presented. At this stage, fast-scan, slow-scan, and step-scan techniques are shown to be virtually equivalent in the mid-IR, but the reduction in frequency dependence of the phase correction and the new capability for VCD measurement in the near-IR favor continued development of step-scan techniques.Keywords
This publication has 19 references indexed in Scilit:
- Instrumental Aspects of Dynamic Two-Dimensional Infrared SpectroscopyApplied Spectroscopy, 1993
- Vibrational circular dichroism of proteins in water solutionJournal of the American Chemical Society, 1993
- A Method for the Determination of the Zero-Path-Difference Position in a Fourier Transform Infrared Spectrometer: Application to Magnetic Vibrational Circular DichroismApplied Spectroscopy, 1991
- Vibrational Circular Dichroism: Comparison of Techniques and Practical ConsiderationsPublished by Elsevier ,1990
- A Solution to the Artifact Problem in Fourier Transform Vibrational Circular DichroismApplied Spectroscopy, 1988
- FOURIER TRANSFORM INFRARED VIBRATIONAL CIRCULAR DICHROISMPublished by Elsevier ,1985
- Vibrational Circular DichroismApplied Spectroscopy Reviews, 1981
- Theory of High Frequency Differential Interferometry: Application to the Measurement of Infrared Circular and Linear Dichroism via Fourier Transform SpectroscopyApplied Spectroscopy, 1979
- Vibrational circular dichroismJournal of the American Chemical Society, 1976
- Polarization scrambling using a photoelastic modulator: Application to circular dichroism measurementJournal of the Optical Society of America, 1975