Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*
Top Cited Papers
- 1 January 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 35 (1) , 64-68
- https://doi.org/10.1097/01.ccm.0000249851.94101.4f
Abstract
Values of central venous pressure of 8–12 mm Hg and of pulmonary artery occlusion pressure of 12–15 mm Hg have been proposed as volume resuscitation targets in recent international guidelines on management of severe sepsis. By analyzing a large number of volume challenges, our aim was to test the significance of the recommended target values in terms of prediction of volume responsiveness. Retrospective study. A 24-bed medical intensive care unit. All consecutive septic patients monitored with a pulmonary artery catheter who underwent a volume challenge between 2001 and 2004. None. A total of 150 volume challenges in 96 patients were reviewed. In 65 instances, the volume challenge resulted in an increase in cardiac index of ≥15% (responders). The pre-infusion central venous pressure was similar in responders and nonresponders (8 ± 4 vs. 9 ± 4 mm Hg). The pre-infusion pulmonary artery occlusion pressure was slightly lower in responders (10 ± 4 vs. 11 ± 4 mm Hg, p < .05). However, the significance of pulmonary artery occlusion pressure to predict fluid responsiveness was poor and similar to that of central venous pressure, as indicated by low values of areas under the receiver operating characteristic curves (0.58 and 0.63, respectively). A central venous pressure of <8 mm Hg and a pulmonary artery occlusion pressure of <12 mm Hg predicted volume responsiveness with a positive predictive value of only 47% and 54%, respectively. With the knowledge of a low stroke volume index (<30 mL·m−2), their positive predictive values were still unsatisfactory: 61% and 69%, respectively. When the combination of central venous pressure and pulmonary artery occlusion pressure was considered instead of either pressure alone, the degree of prediction of volume responsiveness was not improved. Our study demonstrates that cardiac filling pressures are poor predictors of fluid responsiveness in septic patients. Therefore, their use as targets for volume resuscitation must be discouraged, at least after the early phase of sepsis has concluded.Keywords
This publication has 22 references indexed in Scilit:
- Practice parameters for hemodynamic support of sepsis in adult patients: 2004 updateCritical Care Medicine, 2004
- Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shockCritical Care Medicine, 2004
- Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive careIntensive Care Medicine, 2003
- Predicting Fluid Responsiveness in ICU PatientsChest, 2002
- Early Goal-Directed Therapy in the Treatment of Severe Sepsis and Septic ShockNew England Journal of Medicine, 2001
- Relation between Respiratory Changes in Arterial Pulse Pressure and Fluid Responsiveness in Septic Patients with Acute Circulatory FailureAmerican Journal of Respiratory and Critical Care Medicine, 2000
- A bedside index assessing the reliability of pulmonary artery occlusion pressure measurements during mechanical ventilation with positive end-expiratory pressureJournal of Critical Care, 1992
- Measurements of Right Ventricular Volumes during Fluid ChallengeChest, 1990
- Biventricular performance during volume loading in patients with early septic shock, with emphasis on the right ventricle: A combined hemodynamic and radionuclide studyAmerican Heart Journal, 1988
- A method of comparing the areas under receiver operating characteristic curves derived from the same cases.Radiology, 1983