Reverse Phase Thin Layer Chromatography of Some Aroclors, Halowaxes, and Pesticides

Abstract
The components of Aroclors® 1232, 1248, 1254, and 1260; Halowaxes® 1099, 1013, and 1014; and several chlorinated pesticides are resolved by reverse phase thin layer chromatography (RPTLC), which permits component separation by partition between a nonpolar stationary phase and a polar mobile phase. Rf values of resulting spots were calculated for 2 of 4 new solvent systems (mobile phases). RPTLC patterns were reproducible and characteristic of each material examined. The spots were recovered from the plates and characterized by gas-liquid chromatography (GLC) and/or GLC-mass spectrometry. In some cases, single GLC peaks of Aroclor standards were resolved into more than one component by RPTLC, whereas some RPTLC spots of Halowaxes were resolved into as many as 4 GLC peaks. The analysis of environmental residues of chlorinated compounds was facilitated by this technique.