Cardiovascular effects of carbon dioxide in ventilated preterm infants
- 1 June 1992
- journal article
- Published by Wiley in Acta Paediatrica
- Vol. 81 (6-7) , 498-503
- https://doi.org/10.1111/j.1651-2227.1992.tb12282.x
Abstract
Sick preterm infants may, under certain conditions, demonstrate blood pressure passive cerebral blood flow in response to changes in arterial carbon dioxide tension. Blood pressure in turn depends on cardiac output and peripheral resistance. A Doppler technique for assessing cardiac output compared favourably in terms of reproducibility to a thermodilution technique in a group of infants undergoing cardiac catheterization for congenital heart disease. Doppler was subsequently used to monitor changes in cardiac output following an increase in arterial carbon dioxide tension of 1 kPa in 25 ventilated preterm infants. Blood pressure increased significantly (p = 0.006). However, heart rate did not change significantly (p = 0.16) and, in addition, both stroke and minute volume decreased (p = 0.023, p = 0.02, respectively). This suggests that accompanying changes in components of peripheral resistance exert important effects on blood pressure in the preterm neonate in response to changes in arterial carbon dioxide tension.Keywords
This publication has 20 references indexed in Scilit:
- A comparison of thermodilution and pulsed Doppler cardiac output measurement in critically ill childrenThe Journal of Pediatrics, 1989
- Noninvasive cardiac output, Doppler flowmetry, and gold-plated assumptionsCritical Care Medicine, 1987
- Pulsed Doppler echocardiographic assessment, including use of aortic leaflet separation, of cardiac output in children with structural heart diseaseThe American Journal of Cardiology, 1986
- The continuous measurement of intra-arterial pressure in the neonate: method and accuracyClinical Physics and Physiological Measurement, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Determination of cardiac output by transcutaneous continuous-wave ultrasonic Doppler computerThe American Journal of Cardiology, 1984
- Noninvasive pulsed Doppler determination of cardiac output in neonates and childrenThe Journal of Pediatrics, 1982
- Cardiovascular Effects of Carbon Dioxide in ManAnesthesiology, 1974
- GENERAL AND REGIONAL CIRCULATORY RESPONSES TO CHANGE IN BLOOD PH AND CARBON DIOXIDE TENSION*Journal of Clinical Investigation, 1961
- EFFECTS OF CARBON DIOXIDE ON THE CARDIOVASCULAR SYSTEMAnesthesiology, 1960