Measurement of Stroke Volume with Three-dimensional Transesophageal Ultrasonic Scanning
- 1 March 1989
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 70 (3) , 470-476
- https://doi.org/10.1097/00000542-198903000-00017
Abstract
The accuracy of measuring cardiac stroke volume with a new transesophageal phased array ultrasonic probe was investigated in 10 dogs. The method involved scanning the heart to obtain serial images covering the entire left ventricular cavity at end-expiration. An off-line computer analysis of the images was used to form three-dimensional reconstructions of the left ventricular cavity at end-diastole and end-systole, from which stroke volume was determined. Comparison with stroke volume determined by thermodilution during a wide range of hemodynamic conditions gave the following results for least-squares regression on 57 determinations (with the 95% confidence limits in parentheses): slope 0.95 (0.842–1.06), or-dinate intercept 2.1 (2.0–2.2) ml, standard error of the estimate 4.1 ml, and correlation coefficient of 0.92 (0.87–0.95). Histologic examination of sections of esophagus surrounding the tip of the probe in nine dogs demonstrated minimal trauma to the esophageal wall, with eight specimens described as normal and one showing mild inflammation. The authors conclude that three-dimensional reconstruction of the left ventricular cavity from multiple transesophageal images offers a safe and accurate, although presently tedious, method for determining stroke volume.This publication has 13 references indexed in Scilit:
- Left Ventricular DilatationChest, 1985
- The left ventricular dP/dtmax-end-diastolic volume relation in closed-chest dogs.Circulation Research, 1985
- Effect of regional ischemia on the left ventricular end-systolic pressure-volume relation in chronically instrumented dogsJournal of the American College of Cardiology, 1985
- INTRAOPERATIVE MONITORING BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY1985
- Prognostic significance of left ventricular ejection fraction after acute myocardial infarction. A bedside radionuclide study.Heart, 1985
- Validation of a computerized edge detection algorithm for quantitative two-dimensional echocardiography.Circulation, 1983
- Assessment of quantitative methods for 2-dimensional echocardiographyThe American Journal of Cardiology, 1983
- RELIABILITY OF THE THERMODILUTION METHOD IN THE DETERMINATION OF CARDIAC-OUTPUT IN CLINICAL-PRACTICEPublished by Elsevier ,1982
- Relationship of wedge pressure to end-diastolic volume in patients undergoing myocardial revascularizationThe Journal of Thoracic and Cardiovascular Surgery, 1979
- The ventricular pressure-volume diagram revisited.Circulation Research, 1978