Electrocardiogram‐correlated image reconstruction from subsecond spiral computed tomography scans of the heart
- 3 December 1998
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 25 (12) , 2417-2431
- https://doi.org/10.1118/1.598453
Abstract
Subsecond computed tomography (CT) scanning offers potential for improved heart imaging. We therefore developed and validated dedicated reconstruction algorithms for imaging the heart with subsecond spiral CT utilizing electrocardiogram (ECG) information. We modified spiral CT z‐interpolation algorithms on a subsecond spiral CT scanner. Two new classes of algorithms were investigated: (a) 180°CI (cardio interpolation), a piecewise linear interpolation between adjacent spiral data segments belonging to the same heart phase where segments are selected by correlation with the simultaneously recorded ECG signal and (b) 180°CD (cardio delta), a partial scan reconstruction of with angle, resulting in reduced effective scan times of less than 0.5 s. Computer simulations as well as processing of clinical data collected with 0.75 s scan time were carried out to evaluate these new approaches. Both 180°CI and 180°CD provided significant improvements in image quality. Motion artifacts in the reconstructed images were largely reduced as compared to standard spiral reconstructions; in particular, coronary calcifications were delineated more sharply and multiplanar reformations showed improved contiguity. However, new artifacts in the image plane are introduced, mostly due to the combination of different data segments. ECG‐oriented image reconstructions improve the quality of heart imaging with spiral CT significantly. Image quality and the display of coronary calcification appear adequate to assess coronary calcium measurements with conventional subsecond spiral CT.Keywords
This publication has 10 references indexed in Scilit:
- Coronary arteries: retrospective cardiac gating technique to reduce cardiac motion artifact at spiral CT.Radiology, 1997
- Calcification of coronary arteries: detection and quantification with double-helix CT.Radiology, 1995
- Electron-beam CT: use of a calibration phantom to reduce variability in calcium quantitation.Radiology, 1995
- Helical CT image noise-analytical resultsMedical Physics, 1993
- Evaluation of section sensitivity profiles and image noise in spiral CT.Radiology, 1992
- Physical performance characteristics of spiral CT scanningMedical Physics, 1991
- Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.Radiology, 1990
- Quantification of coronary artery calcium using ultrafast computed tomographyJournal of the American College of Cardiology, 1990
- Cardiac computed tomographyProceedings of the IEEE, 1983
- Computed tomography of the heart: ECG-gated and continuous scans.Radiology, 1981