Influence of magnetic source imaging for planning intracranial EEG in epilepsy
- 23 September 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Neurology
- Vol. 71 (13) , 990-996
- https://doi.org/10.1212/01.wnl.0000326591.29858.1a
Abstract
Background: Magnetic source imaging (MSI) is used routinely in epilepsy presurgical evaluation and in mapping eloquent cortex for surgery. Despite increasing use, the diagnostic yield of MSI is uncertain, with reports varying from 5% to 35%. To add benefit, a diagnostic technique should influence decisions made from other tests, and that influence should yield better outcomes. We report preliminary results of an ongoing, long-term clinical study in epilepsy, where MSI changed surgical decisions. Methods: We determined whether MSI changed the surgical decision in a prospective, blinded, crossover-controlled, single-treatment, observational case series. Sixty-nine sequential patients diagnosed with partial epilepsy of suspected neocortical origin had video-EEG and imaging. All met criteria for intracranial EEG (ICEEG). At a surgical conference, a decision was made before and after presentation of MSI. Cases where MSI altered the decision were noted. Results: MSI gave nonredundant information in 23 patients (33%). MSI added ICEEG electrodes in 9 (13%) and changed the surgical decision in another 14 (20%). Based on MSI, 16 patients (23%) were scheduled for different ICEEG coverage. Twenty-eight have gone to ICEEG, 29 to resection, and 14 to vagal nerve stimulation, including 17 where MSI changed the decision. Additional electrodes in 4 patients covered the correct: hemisphere in 3, lobe in 3, and sublobar ictal onset zone in 1. MSI avoided contralateral electrodes in 2, who both localized on ICEEG. MSI added information to ICEEG in 1. Conclusion: Magnetic source imaging (MSI) provided nonredundant information in 33% of patients. In those who have undergone surgery to date, MSI added useful information that changed treatment in 6 (9%), without increasing complications. MSI has benefited 21% who have gone to surgery.This publication has 31 references indexed in Scilit:
- Magnetic source imaging versus intracranial electroencephalogram in epilepsy surgery: A prospective studyAnnals of Neurology, 2006
- Magnetoencephalography source localization and surgical outcome in temporal lobe epilepsyClinical Neurophysiology, 2004
- Magnetic brain source imaging of focal epileptic activity: a synopsis of 455 casesBrain, 2003
- Magnetoencephalography-directed surgery in patients with neocortical epilepsyJournal of Neurosurgery, 2002
- Magnetoencephalographic mapping of the language-specific cortexJournal of Neurosurgery, 1999
- Multichannel Magnetoencephalography in Ablative Seizure Surgery Outside the Anteromesial Temporal LobeStereotactic and Functional Neurosurgery, 1995
- Localization of magnetic interictal discharges in temporal lobe epilepsyAnnals of Neurology, 1987
- Changes in epileptic spike configuration associated with attainment of seizure controlAnnals of Neurology, 1986
- Surface and Deep EEG Correlates of Surgical Outcome in Temporal Lobe EpilepsyEpilepsia, 1981
- Correlation of criteria used for localizing epileptic foci in patients considered for surgical therapy of epilepsyAnnals of Neurology, 1981