Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical considerations
- 1 October 1992
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 37 (10) , 1883-1900
- https://doi.org/10.1088/0031-9155/37/10/006
Abstract
A minimally perturbing plastic scintillation detector has been developed for the dosimetry of high-energy beams in radiotherapy. The detector system consists of two identical parallel sets of radiation-resistant optical fibre bundles, each connected to independent photomultiplier tubes (PMT). One fibre bundle is connected to a miniature water-equivalent plastic scintillator and so scintillation as well as Cerenkov light generated in the fibres is detected at its PMT. The other 'background' bundle is not connected to the scintillator and so only Cerenkov light is detected by its PMT. The background signal is subtracted to yield only the signal from the scintillator. The water-equivalence of plastic scintillation detectors is studied for photon and electron beams in the radiotherapy range. Application of Burlin cavity theory shows that the energy dependence of such detectors is expected to be better than the commonly used systems. It is also shown that they are not affected by temperature variations and exhibit much less radiation damage than either photon or electron diode detectors.Keywords
This publication has 15 references indexed in Scilit:
- Analysis of response data for several organic scintillatorsPublished by Elsevier ,2002
- Photon mass attenuation and energy-absorption coefficientsPublished by Elsevier ,2002
- Cerenkov light generated in optical fibres and other light pipes irradiated by electron beamsPhysics in Medicine & Biology, 1992
- The response of NE-102 plastic scintillator to stopped 3He nucleiNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1986
- Influence of electron path length on the evaluation of Burlin's cavity theoryThe British Journal of Radiology, 1982
- A solid water phantom material for radiotherapy x-ray and γ-ray beam calibrationsMedical Physics, 1982
- Spectrum perturbation and energy deposition models for stopping power ratio calculations in general cavity theoryPhysics in Medicine & Biology, 1974
- Measurement of the response of several organic scintillators to electrons, protons and deuteronsNuclear Instruments and Methods, 1968
- A General Theory of Cavity IonisationThe British Journal of Radiology, 1966
- The response of plastic scintillators to high-energy particlesNuclear Instruments and Methods, 1960