Energy-shunting external hip protector attenuates the peak femoral impact force below the theoretical fracture threshold: An in vitro biomechanical study under falling conditions of thel elderly
- 1 October 1995
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 10 (10) , 1437-1442
- https://doi.org/10.1002/jbmr.5650101003
Abstract
The first objective of this study was to design a hip protector that would effectively attenuate and shunt away from the greater trochanter the impact energies created in typical falls of the elderly. As the shock absorption material, the protector included the 12 mm-thick Plastazote, which was found to be the most efficient energy-absorbing material in our previous in vitro biomechanical tests. With an anatomically designed semiflexible outer shield of the protector (high density polyethylene), the impact surface was increased and the impact energy shunted away from the greater trochanter. In the second phase of the study, we determined the force attenuation capacity of this device in realistic (in vitro) falling conditions of the elderly. With the impact force of 6940 N used (a typical hip impact force measured in in vitro falling tests), the trochanteric soft tissue (25 mm-thick polyethylene foam) attenuated the peak femoral impact force to 5590 N and the tested protector to 1040 N. In the second series of this experiment, the peak femoral impact force was set to be so high (13,130 N) that the protector, if effective, should prevent the hip fracture in almost all cases. The trochanteric soft tissue attenuated this peak impact force to 10,400 N and the tested protector to 1810 N. Thus, the force received by the proximal femur still remained clearly below 4170 N, the average force required to fracture in vitro the proximal femur of the elderly in a fall loading configuration. In conclusion, our test results suggest that an anatomically designed energy-shunting and energy-absorbing hip protector can provide an effective impact force attenuation in typical falling conditions of the elderly. However, the efficacy of the protector in the prevention of hip fractures can only be evaluated in randomized clinical trials.Keywords
This publication has 30 references indexed in Scilit:
- Energy-Shunting Hip Padding System Attenuates Femoral Impact Force in a Simulated FallJournal of Biomechanical Engineering, 1995
- Force attenuation properties of various trochanteric padding materials under typical falling conditions of the elderlyJournal of Bone and Mineral Research, 1994
- Effects of loading rate on strength of the proximal femurCalcified Tissue International, 1994
- Hip fractures in the elderly: A world-wide projectionOsteoporosis International, 1992
- Perspective how many women have osteoporosis?Journal of Bone and Mineral Research, 1992
- Prediction of Femoral Impact Forces in Falls on the HipJournal of Biomechanical Engineering, 1991
- Incidence of hip fractures in the elderly: A cross-national analysisOsteoporosis International, 1991
- The incidence of hip fracture in Finland in the year 2000Acta Orthopaedica, 1991
- The Future of Hip Fractures in the United StatesPublished by Wolters Kluwer Health ,1990
- Risk Factors for Falls among Elderly Persons Living in the CommunityNew England Journal of Medicine, 1988