Non‐invasive cardiac output assessment during moderate exercise: pulse contour compared with CO2 rebreathing
- 28 June 1999
- journal article
- research article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 19 (3) , 230-237
- https://doi.org/10.1046/j.1365-2281.1999.00166.x
Abstract
The arterial pulse contour method called Modelflow 2·1 calculates stroke volume continuously, beat to beat, from the non‐invasive blood pressure signal measured by Finapres or Portapres. Portapres is the portable version of Finapres. The purpose of this study was to compare cardiac output (CO) calculated using Modelflow 2·1 (COmf) with CO obtained by the CO2 rebreathing method (COre) during steady state at moderate exercise levels. Twelve subjects visited the laboratory twice and performed submaximal exercise on a bicycle ergometer at 20%, 40% and 60% of their individual peak power output (POpeak). The averaged correlation between COmf and COre gives an r‐value of 0·69, whereas the slope and intercept of the regression line were 1·06 and 1·65 respectively. The averaged difference between COmf and COre was 2·27 ± 3·9 l min–1 (mean ± standard deviation). However, the test–retest difference between COmf and COre was 2·5 ± 3·1 and 0·5 ± 1·3 l min–1 respectively. These results suggest that Modelflow 2·1 is not an accurate method for estimating CO from non‐invasive blood pressure data collected by Portapres during exercise at up to 60% of the individual POpeak corresponding with daily life activity.Keywords
This publication has 16 references indexed in Scilit:
- Influence of sympathetic stimulation on the mechanical properties of the aorta in humansActa Physiologica Scandinavica, 1997
- Comparison of intrabrachial and finger blood pressure in healthy elderly volunteersAmerican Journal of Hypertension, 1995
- Cardiac output determined by the CO2rebreathing method during arm exerciseClinical Physiology and Functional Imaging, 1994
- Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.Hypertension, 1993
- Continuous noninvasive cardiac output as estimated from the pulse contour curveJournal of Clinical Monitoring and Computing, 1992
- Continuous cardiac output monitoring by pulse contour during cardiac surgeryEuropean Heart Journal, 1990
- Comparison of Finapres non-invasive beat-to-beat finger blood pressure with intrabrachial artery pressure during and after bicycle ergometryJournal Of Hypertension, 1989
- Increases in plasma neuropeptide Y concentrations during sympathetic activation in manJournal of the Autonomic Nervous System, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Reliability of the cardiac output measurement with the indirect Fick-principle for CO2 during exercisePflügers Archiv - European Journal of Physiology, 1980