Electrical stimulation of bone growth into porous Al2O3
- 1 March 1976
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 10 (2) , 231-247
- https://doi.org/10.1002/jbm.820100205
Abstract
Porous, cylindrical, high alumina, ceramic structures were fabricated for implantation in the superior third of canine femoral medullary canals. Implant durations of one, two, four, and eight weeks using three animals per time period were studied. A constant current (10 μA) power supply was used to attempt to stimulate bone growth into the porous ceramic structures. Osseous tissue ingrowth was evaluated using a mechanical push‐out test, microradiography, and histological thin sectioning. The interfacial shear strength and tissue microstructure was studied as a function of implant residence site and implant residence time.The results indicate that initially the proximal implants have a higher interfacial shear strength, however, after eight weeks of implantation the distal implants have a shear strength about twice that of the proximal implants. This trend is observed for both the electrically stimulated and nonstimulated specimens. The 10 μA current level used in this investigation was found to have a small but significant effect on shear strength increasing it at implantation times of less than eight weeks.Keywords
This publication has 15 references indexed in Scilit:
- The normal circulation of bone and its response to surgical interventionJournal of Biomedical Materials Research, 1974
- Kinetics of bone growth into cylindrical channels in aluminum oxide and titaniumJournal of Biomedical Materials Research, 1972
- Porous methyl methacrylate as an implant materialJournal of Biomedical Materials Research, 1972
- Application of porous ceramics for the attachment of load bearing internal orthopedic applicationsJournal of Biomedical Materials Research, 1971
- Porous titanium surgical implant materialsJournal of Biomedical Materials Research, 1971
- HEALING OF NONUNION OF THE MEDIAL MALLEOLUS BY MEANS OF DIRECT CURRENTPublished by Wolters Kluwer Health ,1971
- An evaluation of inert and resorbale ceramics for future clinical orthopedic applicationsJournal of Biomedical Materials Research, 1971
- Preliminary evaluation of porous metal surfaced titanium for orthopedic implantsJournal of Biomedical Materials Research, 1970
- Effects of Electric Current on Bone in vivoNature, 1969
- Effects of Electric Currents on Bone In VivoNature, 1964