Simultaneous real‐time visualization of the catheter tip and vascular anatomy for MR‐guided PTA of iliac arteries in an animal model
Open Access
- 23 July 2002
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 16 (2) , 201-208
- https://doi.org/10.1002/jmri.10148
Abstract
Purpose To examine the feasibility of simultaneous MR real-time active tip tracking and near real-time depiction of the vascular anatomy for percutaneous angioplasty of iliac arteries under MR guidance. Materials and Methods Nine surgically created stenoses of external iliac arteries in pigs were dilated with MR-compatible balloon catheters (Cordis, Roden, The Netherlands). These catheters were equipped with a microcoil for active tracking of the catheter tip with an in-plane update rate of 10 positions per second. The procedures were performed on an interventional 1.5 T Gyroscan ACS-NT scanner (Philips, Best, The Netherlands). Real-time calculation of images acquired by radial k-space filling was performed on a specially designed backprojector exploiting the sliding window reconstruction technique (Philips Research Laboratories, Hamburg, Germany). The image update rate was 20 frames per second using a radial gradient-echo technique (TR = 12 msec, TE = 3.3 msec, 300 radials). MR angiography and X-ray digital subtraction angiography on the X-ray system positioned in-line next to the interventional MR system served as control for the angioplasty results. Results Real-time guidance and positioning of the balloon catheters was possible. The actual position of the catheter tip was indicated in the MR images without any time delay for the reconstruction of the anatomical MR images, which were updated with a rate of 20 frames per second. This yielded a combination of a roadmap and fluoroscopy image, in which the catheter position and the anatomical background image both were continuously updated in real time. Six out of nine stenoses were successfully dilated. The effects of the angioplasty could be visualized by the real-time MR technique, as was proven by X-ray digital subtraction angiography. Conclusion Active tip tracking simultaneous with MRI of the vascular anatomy—both in real time—is possible with the applied technique, enabling MR-guided percutaneous dilatation (PTA) of iliac arteries. J. Magn. Reson. Imaging 2002;16:201–208.Keywords
This publication has 20 references indexed in Scilit:
- Real-time MR Guidance for Inferior Vena Cava Filter Placement in an Animal ModelJournal of Vascular and Interventional Radiology, 2001
- Intravascular MR Imaging-guided Balloon Angioplasty With an MR Imaging Guide Wire: Feasibility Study in RabbitsRadiology, 2000
- Real-time MR fluoroscopy for MR-guided iliac artery stent placementJournal of Magnetic Resonance Imaging, 2000
- Active MR guidance of interventional devices with target-navigationMagnetic Resonance in Medicine, 2000
- Endovascular Treatment of Experimental Canine Aneurysms: Feasibility with MR Imaging GuidanceRadiology, 2000
- MR-guided Angioplasty of Renal Artery Stenosis in a Pig Model: A Feasibility StudyJournal of Vascular and Interventional Radiology, 2000
- MR-guided Transjugular Portosystemic Shunt Placement in a Swine ModelJournal of Vascular and Interventional Radiology, 1999
- MR imaging-guided intravascular procedures: initial demonstration in a pig model.Radiology, 1997
- Visualization of dedicated catheters using fast scanning techniques with potential for MR‐guided vascular interventionsMagnetic Resonance in Medicine, 1996
- Real‐time position monitoring of invasive devices using magnetic resonanceMagnetic Resonance in Medicine, 1993