Endovascular Repair of Thoracic Aortic Aneurysm in Dogs: Evaluation of a Nitinol-Polyester Self-Expanding Stent-Graft
- 1 February 2000
- journal article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 7 (1) , 47-67
- https://doi.org/10.1177/152660280000700108
Abstract
Purpose: To validate the ease of deployment and in vivo healing performance of a nitinol-polyester self-expanding stent-graft using a canine thoracic aortic aneurysm model. Methods: Arterial aneurysms were surgically created in 8 dogs by sewing a polyester patch onto the anterior side of the thoracic aorta. The nitinol-polyester self-expandable stent-grafts (Cragg EndoPro System 1) were implanted transluminally via the femoral route and deployed at the site of the thoracic aneurysm. Aneurysm exclusion and endograft patency were assessed by angiography after implantation and before animal sacrifice at scheduled periods ranging from 1 week to 3 months. The explanted specimens were examined with magnetic resonance imaging (MRI) to study the position of the stent-graft with respect to the aneurysmal sac. Histological analysis using light microscopy and scanning electron microscopy was performed to examine the inflammatory response and healing characteristics of the device. Results: Seven of 8 stent-grafts were implanted successfully; a bend occurred within the aneurysmal sac in 1 dog, which led to continued perfusion of side branches. This endoleak sealed spontaneously within 1 week, and complete exclusion of the aneurysms in all 8 animals continued throughout implantation. At the time of explantation, all devices were structurally intact and well positioned in the aneurysmal sac. At 1 week, the luminal surface displayed a thin layer of thrombotic matrix, which was gradually replaced by a collagenous internal capsule with endothelial-like cell coverage along both ends of the stent-grafts at 2 and 3 months. No exacerbated inflammatory reaction due to either the nitinol wires or the polyester sleeve was observed after 3 months of implantation. Conclusions: This short-term in vivo study of a nitinol-polyester self-expanding endograft demonstrated the effective exclusion of thoracic aneurysms with a satisfactory healing response and no excessive tissue or inflammatory reactions.Keywords
This publication has 23 references indexed in Scilit:
- Endoluminal Treatment of Infrarenal Aortic Aneurysms: Clinical Experience with the Talent Stent-Graft SystemJournal of Vascular and Interventional Radiology, 1999
- AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms: Multicenter prospective clinical trialJournal of Vascular Surgery, 1999
- The EVT Tube and Bifurcated Endograft Systems: Technical Considerations and Clinical SummaryJournal of Endovascular Therapy, 1997
- Three-Year Experience with the White-Yu Endovascular GAD Graft for Transluminal Repair of Aortic and Iliac AneurysmsJournal of Endovascular Therapy, 1997
- Cragg Endopro System I: Early Experience. I. Femoral ArteriesJournal of Vascular and Interventional Radiology, 1997
- Deployment Technique and Histopathological Evaluation of an Endoluminal Vascular Prosthesis Used to Repair an Iliac Artery AneurysmJournal of Endovascular Therapy, 1996
- Results of Autopsy 7 Months after Successful Endoluminal Treatment of an Infrarenal Abdominal Aortic AneurysmJournal of Endovascular Therapy, 1995
- Human transluminally placed endovascular stented grafts: Preliminary histopathologic analysis of healing grafts in aortoiliac and femoral artery occlusive diseaseJournal of Vascular Surgery, 1995
- Transluminal Placement of Endovascular Stent-Grafts for the Treatment of Descending Thoracic Aortic AneurysmsNew England Journal of Medicine, 1994
- Initial Experience with the Cragg Endopro System 1 for Intraluminal Treatment of Peripheral Vascular DiseaseJournal of Endovascular Therapy, 1994