In vitro platelet interactions in whole human blood exposed to biomaterial surfaces: Insights on blood compatibility
- 1 September 1993
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 27 (9) , 1181-1193
- https://doi.org/10.1002/jbm.820270909
Abstract
A short-term in vitro test to study platelet interactions with biomaterials is described. Using fresh human blood and a modified Chandler loop system, β-thromboglobulin release was measured. Also, adherent platelets were observed by using scanning electron microscopy (SEM) and a colorimetric stain specific for human platelet GPIIIa. Materials studied in these experiments were polyethylene (PE), Biomer, poly(vinyl alcohol) (PVA), and a polyurethane prepared with octadecyl pendant groups (ODCE). Four blood reactions were observed: (1) Platelets continually adhere and activate on the Biomer; (2) platelets initially adhere and activate but then spread to a thin, passivating film on the PE; (3) platelets do not adhere to the PVA surface but continually react with it upon contact; and (4) platelets neither adhere to nor activate on the ODCE surface. Reactions (2) and (4) are considered characteristic of blood-compatible materials. © 1993 John Wiley & Sons, Inc.Keywords
This publication has 15 references indexed in Scilit:
- The electronic aggregometer: A novel device for assessing platelet behavior in bloodPublished by Elsevier ,2002
- Platelet consumption by NHLBI reference materials and SilasticJournal of Biomedical Materials Research, 1991
- Platelet consumption by polyvinyl alcohol coated tubing in caninesJournal of Biomedical Materials Research, 1991
- Synthesis and ESCA surface studies of octadecyl chain‐extended polyurethanesJournal of Polymer Science Part A: Polymer Chemistry, 1989
- In vitro platelet interactions with a heparin–polyvinyl alcohol hydrogelJournal of Biomedical Materials Research, 1989
- Effect of heparin–pva hydrogel on platelets in a chronic canine arterio‐venous shuntJournal of Biomedical Materials Research, 1989
- Summary Abstract: X-ray photoelectron spectroscopy characterization of polymers for biomedical applicationsJournal of Vacuum Science & Technology A, 1988
- Evaluation of the in vitro and ex vivo blood compatibility of primary reference materialsJournal of Biomedical Materials Research, 1986
- Reduction in complement activation from biomaterials by removal of air nuclei from the surface roughnessJournal of Biomedical Materials Research, 1984
- Properties of a heparin‐poly(vinyl alcohol) hydrogel coatingJournal of Biomedical Materials Research, 1983