Computerised intraocular lens calculation: clinical results and predictability.
Open Access
- 1 March 1989
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 73 (3) , 220-224
- https://doi.org/10.1136/bjo.73.3.220
Abstract
The predictability of a theoretical, computer-assisted IOL calculation method and of the Sanders-Retzlaff-Kraff (SRK) method was evaluated from pre- and postoperative biometry in 110 cataractous patients subjected to a routine IOL calculation. With the theoretical method and the preoperative data the refraction was on the average 0.72 D (SD 0.78) more myopic than expected, an error which could be corrected for by (1) substituting the assumed postoperative chamber depth by the actual mean value and (2) adding 0.16 mm to the preoperative axial length. With the postoperative data the error was 0.05 D (SD 0.78) (p greater than 0.05). By the SRK method the refraction was 0.15 D (SD 0.71) and 0.37 D (SD 0.69) more hyperopic than expected with the pre- and the postoperative data respectively. These offset errors could be corrected for in either case by adjusting the assumed A constant in the SRK formula. With appropriate empirical corrections for offset errors the theoretical and the SRK method were similar in accuracy, that is, about 82% of the predictions within +/- 1 D, 99% within +/- 2 D, and 100% within +/- 3 D error. The variation in postoperative refraction after computerised IOL calculation was about one-third of the variation previously seen after implantation of standard power IOL.This publication has 22 references indexed in Scilit:
- Intraocular Lens Power CalculationsArchives of Ophthalmology (1950), 1987
- Theoretical vs Empirical Prediction of Aphakic RefractionArchives of Ophthalmology (1950), 1987
- Theoretical, computer-assisted prediction versus SRK prediction of postoperative refraction after intraocular lens implantationJournal of Cataract & Refractive Surgery, 1987
- Theoretical approach to intraocular lens calculation using Gaussian opticsJournal of Cataract & Refractive Surgery, 1987
- Prediction of intraocular lens position after cataract extractionJournal of Cataract & Refractive Surgery, 1986
- Messung der Bulbuslänge mit verschiedenen Ultraschall-GerätenKlinische Monatsblätter für Augenheilkunde, 1986
- Improving the Predictability of Intraocular Lens Power CalculationsArchives of Ophthalmology (1950), 1986
- A comparison of postoperative refractive results with and without intraocular lens power calculation.British Journal of Ophthalmology, 1986
- A New Posterior Chamber Intraocular Lens Formula for Axial MyopesOphthalmology, 1984
- Calculation of the power of an iris clip lens for distant vision.British Journal of Ophthalmology, 1973