Detection of Staphylococcal Enterotoxin B via Biomolecular Interaction Analysis Mass Spectrometry
Open Access
- 1 September 2003
- journal article
- research article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 69 (9) , 5212-5215
- https://doi.org/10.1128/aem.69.9.5212-5215.2003
Abstract
Detection of Staphylococcus enterotoxin B (SEB) by biomolecular interaction analysis mass spectrometry (BIA/MS) is presented in this work. The BIA/MS experiments were based on a surface plasmon resonance (SPR) MS immunoassay that detects affinity-captured SEB both via SPR and by means of exact and direct mass measurement by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Experiments were performed with standard samples and food samples to assess the BIA/MS limit of detection for SEB and to set the experimental parameters for proper quantitation. Single and double SPR referencing was performed to accurately estimate the amount of the bound toxin. Reproducible detection of 1 ng of SEB per ml, corresponding to affinity capture and MS analysis of ∼500 amol of SEB, was readily achieved from both the standard and mushroom samples. A certain amount of SEB degradation was indicated by the signals in the mass spectra. The combination of MS with SPR-based methods of detection creates a unique approach capable of quantifying and qualitatively analyzing protein toxins from pathogenic organisms.Keywords
This publication has 32 references indexed in Scilit:
- A miniature fiber optic surface plasmon resonance sensor for fast detection of staphylococcal enterotoxin BBiosensors and Bioelectronics, 2002
- Spectral surface plasmon resonance biosensor for detection of staphylococcal enterotoxin B in milkInternational Journal of Food Microbiology, 2002
- Current and emerging commercial optical biosensorsJournal of Molecular Recognition, 2001
- Exploring the limit of detection in biomolecular interaction analysis mass spectrometry (BIA/MS): detection of attomole amounts of native proteins present in complex biological mixturesAnalytica Chimica Acta, 2000
- Surface Plasmon Resonance-Based ImmunoassaysMethods, 2000
- Peer Reviewed: Biomolecular Interaction Analysis Mass Spectrometry.Analytical Chemistry, 2000
- Array biosensor for detection of biohazardsBiosensors and Bioelectronics, 2000
- Surface plasmon resonance sensors: reviewSensors and Actuators B: Chemical, 1999
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988
- Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 1988