Evaluation of Ultrasonic Nebulization for the Analysis of Transient Samples: A Theoretical Model and Practical Considerations
- 1 December 1998
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 52 (12) , 1515-1521
- https://doi.org/10.1366/0003702981943211
Abstract
Three spray chambers designed for use with ultrasonic nebulization have been evaluated for the introduction of transient samples into an inductively coupled plasma. The spray chambers were (1) a conventional Fassel type, (2) a commercially available CETAC spray chamber, and (3) a novel spray chamber design that was constructed in-house. All have different volumes and modes of central-channel gas introduction, and consequently different washout times. Interestingly, they can all be described by the same model for both their washin and washout times. This model was able to predict the time response of the three spray chambers based upon the convolution of a Gaussian and an exponential curve. In particular, the experimental washout times can be successfully fit to an exponential-decay model that pertains to an ideal mixing chamber. It was found that the washin time (Gaussian response) was limited mainly by the nebulization process itself and partly by dispersion of the sample aerosol as dictated by the length of the desolvation assembly and by the length of tubing that carried the dry aerosol to the plasma source. It was determined that the spray chamber washout time is the factor that limits instrument response and that the desolvation system utilized in the study caused no appreciable peak tailing but did slighty broaden the Gaussian peak width caused by a laminar flow profile and by the nebulization event. The newly designed spray chamber offered washout times that are 1.6 and 5.2 times faster than the CETAC and Fassel spray chambers, respectively. The practical limitations of ultrasonic nebulization for the analysis of transient samples is discussed with a focus on spray-chamber design and based upon the simple model that was developed for the response curves of transient samples.Keywords
This publication has 25 references indexed in Scilit:
- Speciation of tin by reversed phase liquid chromatography with inductively coupled plasma mass spectrometric detectionAnalytica Chimica Acta, 1995
- Monodisperse Dried Microparticulate Injector for Analytical InstrumentationAnalytical Chemistry, 1994
- Determination of polycyclic aromatic hydrocarbons by high-performance liquid chromatography-particle beam-mass spectrometryJournal of the American Society for Mass Spectrometry, 1993
- Fundamental Aerosol Studies with an Ultrasonic NebulizerApplied Spectroscopy, 1991
- Ultrasonic micronebulizer inferface for high-performance liquid chromatography with flame photometric detectorAnalytical Chemistry, 1987
- Ultrasonic nebulization of liquid samples for analytical inductively coupled plasma-atomic spectroscopy: an updateSpectrochimica Acta Part B: Atomic Spectroscopy, 1986
- Speciation Studies of Zn and Mg in body Fluids Using Interfaced HPLC and Ultrasonic Nebulizer Flame AASpectroscopy Letters, 1986
- Flow injection analysis with inductively coupled plasma-atomic emission spectroscopy: critical comparison of conventional pneumatic, ultrasonic and direct injection nebulizationSpectrochimica Acta Part B: Atomic Spectroscopy, 1985
- HEWLETT PACKARDAnalytical Chemistry, 1984
- Multielement detection limits and sample nebulization efficiencies of an improved ultrasonic nebulizer and a conventional pneumatic nebulizer in inductively coupled plasma-atomic emission spectrometryAnalytical Chemistry, 1977