Tissue classification based on 3D local intensity structures for volume rendering
Top Cited Papers
- 1 January 2000
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 6 (2) , 160-180
- https://doi.org/10.1109/2945.856997
Abstract
This paper describes a novel approach to tissue classification using three-dimensional (3D) derivative features in the volume rendering pipeline. In conventional tissue classification for a scalar volume, tissues of interest are characterized by an opacity transfer function defined as a one-dimensional (1D) function of the original volume intensity. To overcome the limitations inherent in conventional 1D opacity functions, we propose a tissue classification method that employs a multidimensional opacity function, which is a function of the 3D derivative features calculated from a scalar volume as well as the volume intensity. Tissues of interest are characterized by explicitly defined classification rules based on 3D filter responses highlighting local structures, such as edge, sheet, line, and blob, which typically correspond to tissue boundaries, cortices, vessels, and nodules, respectively, in medical volume data. The 3D local structure filters are formulated using the gradient vector and Hessian matrix of the volume intensity function combined with isotropic Gaussian blurring. These filter responses and the original intensity define a multidimensional feature space in which multichannel tissue classification strategies are designed. The usefulness of the proposed method is demonstrated by comparisons with conventional single-channel classification using both synthesized data and clinical data acquired with CT (computed tomography) and MRI (magnetic resonance imaging) scanners. The improvement in image quality obtained using multichannel classification is confirmed by evaluating the contrast and contrast-to-noise ratio in the resultant volume-rendered images with variable opacity values.Keywords
This publication has 28 references indexed in Scilit:
- Peripheral vascular tree stenoses: detection with subtracted and nonsubtracted MR angiography.Radiology, 1998
- CT angiography with volume rendering: advantages and applications in splanchnic vascular imaging.Radiology, 1996
- Edge detection and ridge detection with automatic scale selectionPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1996
- Angiographic properties of Gd-DTPA-24-cascade-polymer — a new macromolecular MR contrast agentEuropean Journal of Radiology, 1995
- Reduction of partial‐volume artifacts with zero‐filled interpolation in three‐dimensional MR angiographyJournal of Magnetic Resonance Imaging, 1994
- Fast volume rendering using a shear-warp factorization of the viewing transformationPublished by Association for Computing Machinery (ACM) ,1994
- Surface and volume rendering techniques to display 3-D dataIEEE Engineering in Medicine and Biology Magazine, 1993
- Impact of section doubling on MR angiography.Radiology, 1992
- Contrast-to-noise ratios in maximum intensity projection imagesMagnetic Resonance in Medicine, 1992
- Display of surfaces from volume dataIEEE Computer Graphics and Applications, 1988