Immediate and Midterm Results following Treatment of Recently Ruptured Intracranial Aneurysms with the Pipeline Embolization Device
Open Access
- 1 December 2011
- journal article
- clinical trial
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 33 (3) , 487-493
- https://doi.org/10.3174/ajnr.a2797
Abstract
BACKGROUND AND PURPOSE: A number of flow-diverting devices have become available for endovascular occlusion of cerebral aneurysms. This article reports immediate and midterm results in recently ruptured aneurysms treated with the PED. MATERIALS AND METHODS: A prospective registry was established at 3 Australian neurointerventional sites to collect data on ruptured and unruptured aneurysms treated with PED during a 12-month period from August 2009. From this data base of 65 patients, 11 cases of recent aneurysmal SAH were examined. Relevant data including antiplatelet therapy, technical issues, complications, and imaging findings during at least a 6-month period of follow-up were collected and analyzed. RESULTS: Eleven patients had acutely ruptured aneurysms with SAH. Clinical follow-up was available on all cases with imaging follow-up at 6 months in 9 patients. Two patients died from rebleeding during the acute illness. There was no other procedural or delayed significant symptomatic morbidity. Eight aneurysms were occluded with a single case of residual body filling. CONCLUSIONS: PED should be used in SAH with caution, reserved for suitable patients concomitantly treated with endosaccular coiling if possible.Keywords
This publication has 32 references indexed in Scilit:
- Comparison of bioactive coils and bare platinum coils for treatment of intracranial aneurysms: a matched-pair analysisJournal of Neurosurgery, 2010
- CURATIVE RECONSTRUCTION OF A GIANT MIDBASILAR TRUNK ANEURYSM WITH THE PIPELINE EMBOLIZATION DEVICENeurosurgery, 2009
- GDC 360° for the endovascular treatment of intracranial aneurysms: a matched-pair study analysing angiographic outcomes with GDC 3D Coils in 38 patientsNeuroradiology, 2008
- WingSpan Stent System in the endovascular treatment of intracranial aneurysms: clinical experience with midterm follow-up resultsJournal of Neurosurgery, 2008
- HydroCoil Endovascular Aneurysm Occlusion and Packing Study (HELPS Trial): Procedural Safety and Operator-Assessed Efficacy ResultsAmerican Journal of Neuroradiology, 2008
- A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysmsNeuroradiology, 2007
- Balloon-assisted coil embolization of intracranial aneurysms: incidence, complications, and angiography resultsJournal of Neurosurgery, 2006
- Usefulness of the Neuroform Stent for the Treatment of Cerebral Aneurysms: Results at Initial (3–6-mo) Follow-upNeurosurgery, 2005
- International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trialThe Lancet, 2002
- Combined endovascular treatment of dissecting vertebral artery aneurysms by using stents and coilsJournal of Neurosurgery, 2001