Effects of Biocompatible versus Standard Fluid on Peritoneal Dialysis Outcomes
- 1 June 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American Society of Nephrology
- Vol. 23 (6) , 1097-1107
- https://doi.org/10.1681/asn.2011121201
Abstract
The clinical benefits of using “biocompatible” neutral pH solutions containing low levels of glucose degradation products for peritoneal dialysis compared with standard solutions are uncertain. In this multicenter, open-label, parallel-group, randomized controlled trial, we randomly assigned 185 incident adult peritoneal dialysis patients with residual renal function to use either biocompatible or conventional solution for 2 years. The primary outcome measure was slope of renal function decline. Secondary outcome measures comprised time to anuria, fluid volume status, peritonitis-free survival, technique survival, patient survival, and adverse events. We did not detect a statistically significant difference in the rate of decline of renal function between the two groups as measured by the slopes of GFR: −0.22 and −0.28 ml/min per 1.73 m2 per month (P=0.17) in the first year in the biocompatible and conventional groups, respectively, and, −0.09 and −0.10 ml/min per 1.73 m2 per month (P=0.9) in the second year. The biocompatible group exhibited significantly longer times to anuria (P=0.009) and to the first peritonitis episode (P=0.01). This group also had fewer patients develop peritonitis (30% versus 49%) and had lower rates of peritonitis (0.30 versus 0.49 episodes per year, P=0.01). In conclusion, this trial does not support a role for biocompatible fluid in slowing the rate of GFR decline, but it does suggest that biocompatible fluid may delay the onset of anuria and reduce the incidence of peritonitis compared with conventional fluid in peritoneal dialysis.Keywords
This publication has 37 references indexed in Scilit:
- Rationale and design of the balANZ trial: A randomised controlled trial of low GDP, neutral pH versus standard peritoneal dialysis solution for the preservation of residual renal functionBMC Nephrology, 2010
- Epidemiology of peritoneal dialysis: a story of believers and nonbelieversNature Reviews Nephrology, 2009
- Relationship between Dialysis Modality and MortalityJournal of the American Society of Nephrology, 2009
- Impact of Peritoneal Dialysis Solutions on OutcomesPublished by Wiley ,2008
- Randomized controlled study of biocompatible peritoneal dialysis solutions: Effect on residual renal functionKidney International, 2008
- Mortality studies comparing peritoneal dialysis and hemodialysis: What do they tell us?Kidney International, 2006
- The Euro-Balance Trial: The effect of a new biocompatible peritoneal dialysis fluid (balance) on the peritoneal membraneKidney International, 2004
- Glucose degradation products in PD fluids: Do they disappear from the peritoneal cavity and enter the systemic circulation?Kidney International, 2003
- Effect of cause and time of dropout on the residual GFR: A comparative analysis of the decline of GFR on dialysisKidney International, 2001
- Effect of aminoglycoside use on residual renal function in peritoneal dialysis patientsAmerican Journal of Kidney Diseases, 1999