MicroCT analysis of hydroxyapatite bone repair scaffolds created via three‐dimensional printing for evaluating the effects of scaffold architecture on bone ingrowth
- 9 August 2007
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 85A (2) , 371-377
- https://doi.org/10.1002/jbm.a.31484
Abstract
Recent studies have shown that it is now possible to construct tissue-engineered bone repair scaffolds with tight pore size distributions and controlled geometries using 3-D Printing techniques (3DP). This study evaluated two hydroxyapatite (HA) 8-mm diameter discs with controlled architectures in a rabbit trephine defect at 8 and 16 weeks using a 2 × 2 factorial design. Input parameters were time and scaffold void volume at two levels. Three output variables were extracted from MicroCT data: bone volume ingrowth with respect to total region of interest, bone volume ingrowth with respect to available ingrowth volume, and soft tissue volume. The experiment measured two groups—Group 1: 500-μm × 500-μm channels parallel to the scaffold's long axis and penetrating up 3-mm from the bottom. Group 2: 800-μm × 800-μm struts spaced 500 μm apart set perpendicularly to each other in each printed layer. Rendered 3-dimensional MicroCT scans and undecalcified histological slides of implants revealed good integration with the surrounding tissue, and a sizeable amount of bone ingrowth into the device. Factorial analysis revealed that the effects of time were the greatest determinant of soft tissue ingrowth, while time and its interaction with void volume were the greatest determinants of bone volume ingrowth with respect to both total and available volume. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008Keywords
This publication has 26 references indexed in Scilit:
- Sintering and robocasting of β-tricalcium phosphate scaffolds for orthopaedic applicationsActa Biomaterialia, 2006
- Bone response to 3D periodic hydroxyapatite scaffolds with and without tailored microporosity to deliver bone morphogenetic protein 2Journal of Biomedical Materials Research Part A, 2005
- Performance of hydroxyapatite bone repair scaffolds created via three‐dimensional fabrication techniquesJournal of Biomedical Materials Research Part A, 2003
- Engineered cellular response to scaffold architecture in a rabbit trephine defectJournal of Biomedical Materials Research Part A, 2003
- Preparation, characterization, and in vitro degradation of bioresorbable and bioactive composites based on Bioglass®‐filled polylactide foamsJournal of Biomedical Materials Research Part A, 2003
- Resorbable defect analog PLGA scaffolds using CO2 as solvent: Structural characterizationJournal of Biomedical Materials Research, 2002
- Robocast Pb(Zr0.95Ti0.05)O3 Ceramic Monoliths and CompositesJournal of the American Ceramic Society, 2001
- Surface Roughness, Porosity, and Texture as Modifiers of Cellular AdhesionTissue Engineering, 1996
- Investigation of an organic delivery system for demineralized bone matrix in a delayed‐healing cranial defect modelJournal of Biomedical Materials Research, 1994
- Calvarial Reconstruction in Baboons with Porous HydroxyapatiteThe Journal of Craniofacial Surgery, 1992