Thermal Esophageal Lesions After Radiofrequency Catheter Ablation of Left Atrial Arrhythmias
- 1 March 2010
- journal article
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 105 (3) , 551-556
- https://doi.org/10.1038/ajg.2009.625
Abstract
Radiofrequency catheter ablation in patients with left atrial arrhythmias may cause esophageal damage because of the close proximity between the posterior wall of the left atrium and the esophagus. The aim of this prospective study was to determine the incidence, endoscopic characterization, and endoluminal temperature dependency of esophageal thermal lesions after catheter ablation. In all, 185 consecutive patients with symptomatic atrial fibrillation or left atrial macro-re-entrant tachycardia who underwent left atrial radiofrequency catheter ablation were scheduled for upper gastrointestinal endoscopy. During the ablation procedure, a non-fluoroscopic three-dimensional system for catheter orientation, computed tomography (CT) image integration, and activation mapping was used. The esophagus was intubated with a temperature probe for visualization within the three-dimensional image and for real-time intraluminal temperature monitoring. A total of 27 (14.6%) asymptomatic ulcer-like or hemorrhagic esophageal thermal lesions with a diameter of 2-16 mm were observed. Esophageal lesions did not occur below an intraluminal esophageal temperature of 41 degrees C. The maximal temperature in the esophagus was significantly higher in patients with thermal lesions than in patients without lesions (42.6+/-1.7 degrees C vs. 41.4+/-1.7 degrees C, P=0.003). For every 1 degrees C increase in endoluminal temperature, the odds of an esophageal lesion increased by a factor of 1.36 (95% confidence interval (CI) 1.07-1.74, P=0.012). No progression of the lesions was observed during follow-up endoscopies. Localized esophageal ulcer-like lesion is a frequent event after left atrial catheter ablation and can be found in patients whose intraluminal temperature has reached at least 41 degrees C.Keywords
This publication has 13 references indexed in Scilit:
- Safe and Effective Ablation of Atrial Fibrillation: Importance of Esophageal Temperature Monitoring to Avoid Periesophageal Nerve Injury as a Complication of Pulmonary Vein IsolationJournal of Cardiovascular Electrophysiology, 2008
- Esophageal Injury and Temperature Monitoring During Atrial Fibrillation AblationCirculation: Arrhythmia and Electrophysiology, 2008
- Ablation of atrial fibrillationHerzschrittmachertherapie + Elektrophysiologie, 2008
- Computed tomography model-based treatment of atrial fibrillation and atrial macro-re-entrant tachycardiaEP Europace, 2008
- Incidence of oesophageal wall injury post-pulmonary vein antrum isolation for treatment of patients with atrial fibrillationEP Europace, 2008
- Brief Communication: Atrial–Esophageal Fistulas after Radiofrequency AblationAnnals of Internal Medicine, 2006
- Circumferential Pulmonary-Vein Ablation for Chronic Atrial FibrillationNew England Journal of Medicine, 2006
- Anatomic Relations Between the Esophagus and Left Atrium and Relevance for Ablation of Atrial FibrillationCirculation, 2005
- Assessment of Temperature, Proximity, and Course of the Esophagus During Radiofrequency Ablation Within the Left AtriumCirculation, 2005
- Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial FibrillationCirculation, 2004