Evaluation of low‐pressure gas chromatography linked to ion‐trap tandem mass spectrometry for the fast trace analysis of multiclass pesticide residues
- 16 May 2002
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (12) , 1216-1224
- https://doi.org/10.1002/rcm.707
Abstract
A rapid multiresidue method for the analysis of 72 pesticides has been developed using a single injection with low‐pressure gas chromatography/tandem mass spectrometry (LP‐GC/MS/MS). The LP‐GC/MS/MS method used a short capillary column of 10 m × 0.53 mm i.d. × 0.25 µm film thickness coupled with a 0.6 m × 0.10 mm i.d. restriction at the inlet end. Optimal LP‐GC conditions were determined which achieved the fastest separation in MS/MS detection mode. Also MS/MS conditions were optimized in order to increase sensitivity and selectivity. The analytical parameters of the LP‐GC/MS/MS method were compared with those obtained by GC/MS/MS using a conventional capillary column (30 m × 0.25 mm i.d. × 0.25 µm film thickness). Better precision and sensitivity values were obtained with the LP‐GC/MS/MS approach. The limits of detection (LOD) of the compounds ranged from 0.1 to 14.1 µg L−1 for LP‐GC/MS/MS, lower than those obtained for conventional GC/MS/MS that ranged from 0.1 to 17.5 µg L−1. The peak widths obtained with the short column in LP‐GC are similar to those obtained using conventional capillary GC columns, and the peaks can be successfully identified by MS/MS detection with the conventional scan speed of ion‐trap instruments. In addition, the analysis time was significantly reduced with LP‐GC/MS/MS (32 min) versus GC/MS/MS (72 min), allowing the number of samples analyzed per day in a routine laboratory to be doubled. Copyright © 2002 John Wiley & Sons, Ltd.Keywords
Funding Information
- INIA (CAL00-064)
- FIAPA (Ce.-486/01)
This publication has 32 references indexed in Scilit:
- Theory of Fast Capillary Gas Chromatography - Part 3: Column Performancevs. Gas Flow RateJournal of High Resolution Chromatography, 1999
- Analysis of Pesticides in Water Samples Using GC-ECD and GC-MS/MS TechniquesInternational Journal of Environmental Analytical Chemistry, 1999
- Packed Capillary Column Solvating Gas Chromatography Using Mobile Phases That Transition from Liquid to Gas between the Column Inlet and OutletAnalytical Chemistry, 1998
- Megabore versus microbore as the optimal column for fast gas chromatography/mass spectrometryEuropean Journal of Mass Spectrometry, 1998
- Theory of fast capillary gas chromatography part. 2: Speed of analysisJournal of High Resolution Chromatography, 1997
- Theory of fast capillary gas chromatography. Part 1: Column efficiencyJournal of High Resolution Chromatography, 1997
- Large-volume injection in gas chromatography-ion trap tandem mass spectrometry for the determination of pesticides in the marine environment at the low ng/l levelAnalytica Chimica Acta, 1997
- Theoretical and practical aspects of short open tubular columns at subambient pressures in gas chromatography/mass spectrometryAnalytical Chemistry, 1989
- Turbulent flow in capillary gas chromatographyJournal of Chromatography A, 1989
- Theoretical aspects and practical potentials of rapid gas analysis in capillary gas chromatographyAnalytical Chemistry, 1987