Influence of Refraction on Tonometric Readings After Photorefractive Keratectomy and Laser Assisted In Situ Keratomileusis
- 1 July 2000
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Cornea
- Vol. 19 (4) , 512-516
- https://doi.org/10.1097/00003226-200007000-00022
Abstract
To determine the decrease of Goldmann tonometry after photorefractive keratectomy (PRK) and laser assisted in situ keratomileusis (LASIK) according to refraction prior to surgery. Prospective simultaneous comparative case series of 53 myopic eyes (53 patients) that underwent PRK and 50 (50 patients) that underwent LASIK using the Summit Excimed SVS plus (Summit Technology, Inc., Walthan, MA, U.S.A.). PRK and LASIK were subdivided by refractive error into two subgroups of more than or less than -5 diopters (D). Central tonometric readings were taken prior to surgery and 12 months after surgery. In LASIK and PRK subgroups of more than -5 D, 85.7% (24) and 69.6% (24), respectively, gave lower readings than those taken before surgery. In LASIK and PRK subgroups of less than -5 D, 77.3% (17) and 53.3% (16), respectively, gave lower readings. The difference between the two is significant (p < 0.001). Average tonometry falls by 2.8 mmHG in the LASIK subgroup of more than -5 D (p < 0.001) and by 2.8 mmHG in the LASIK subgroup of less than -5 D (p < 0.001) and by 1.7 mmHG in the PRK subgroup of more than -5 D (p < 0.010). In PRK subgroup of less than -5 D, the tonometric changes are not significant (p = 0.971). High previous refraction (in PRK) and technique used determines lower final tonometric readings, bringing about more frequent and significant decreases in LASIK than in PRK for errors of more than and less than -5 D.Keywords
This publication has 26 references indexed in Scilit:
- Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomyOphthalmology, 1998
- Komplikationen der photorefraktiven Keratektomie zur MyopiekorrekturDer Ophthalmologe, 1998
- Positive correlation between Tono-pen intraocular pressure and central corneal thicknessOphthalmology, 1998
- Non-Contact Tonometry in Patients that Underwent Photorefractive KeratectomyOphthalmologica, 1997
- Increased intraocular pressure with corticosteroid medication after photorefractive keratectomySurvey of Ophthalmology, 1996
- Punktuelle Ablation des Trabekelwerks mit dem Exzimerlaser beim primären OffenwinkelglaukomDer Ophthalmologe, 1996
- Excimer laser photorefractive keratectomySurvey of Ophthalmology, 1995
- Sources of error with use of Goldmann-type tonometersSurvey of Ophthalmology, 1993
- Measurement of intraocular pressure: A study of its reproducibilityAlbrecht von Graefes Archiv für Ophthalmologie, 1976
- APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESSActa Ophthalmologica, 1975