Clinical multishot DW‐EPI through parallel imaging with considerations of susceptibility, motion, and noise
Open Access
- 24 April 2007
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 57 (5) , 881-890
- https://doi.org/10.1002/mrm.21176
Abstract
Geometric distortions and poor image resolution are well known shortcomings of single‐shot echo‐planar imaging (ss‐EPI). Yet, due to the motion immunity of ss‐EPI, it remains the most common sequence for diffusion‐weighted imaging (DWI). Moreover, both navigated DW interleaved EPI (iEPI) and parallel imaging (PI) methods, such as sensitivity encoding (SENSE) and generalized autocalibrating parallel acquisitions (GRAPPA), can improve the image quality in EPI. In this work, DW‐EPI accelerated by PI is proposed as a self‐calibrated and unnavigated form of interleaved acquisition. The PI calibration is performed on the b = 0 s/mm2 data and applied to each shot in the rest of the DW data set, followed by magnitude averaging. Central in this study is the comparison of GRAPPA and SENSE in the presence of off‐resonances and motion. The results show that GRAPPA is more robust than SENSE against both off‐resonance and motion‐related artifacts. The SNR efficiency was also investigated, and it is shown that the SNR/scan time ratio is equally high for one‐ to three‐shot high‐resolution diffusion scans due to the shortened EPI readout train length. The image quality improvements without SNR efficiency loss, together with motion tolerance, make the GRAPPA‐driven DW‐EPI sequence clinically attractive. Magn Reson Med 57:881–890, 2007.Keywords
This publication has 31 references indexed in Scilit:
- Influence of SENSE on image properties in high‐resolution single‐shot echo‐planar DTIMagnetic Resonance in Medicine, 2006
- 3Parallel magnetic resonance imaging with adaptive radius in k‐space (PARS): Constrained image reconstruction using k‐space locality in radiofrequency coil encoded dataMagnetic Resonance in Medicine, 2005
- Field‐of‐view limitations in parallel imagingMagnetic Resonance in Medicine, 2004
- Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echoMagnetic Resonance in Medicine, 2002
- Diffusion tensor imaging using single‐shot SENSE‐EPIMagnetic Resonance in Medicine, 2002
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- VD‐AUTO‐SMASH imagingMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental resultsMagnetic Resonance in Medicine, 1996
- Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imagingMagnetic Resonance in Medicine, 1990