Computing patient doses of X-ray examinations using a patient size- and sex-adjustable phantom.
- 1 July 1997
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 70 (835) , 708-718
- https://doi.org/10.1259/bjr.70.835.9245883
Abstract
Both the use of traditional fluoroscopy and the increasing use of modern digital techniques in radiology and interventional radiology demand the development of versatile computer programs for patient dose determinations. Long computing times restrict the use of Monte Carlo (MC) methods in dose monitoring applications where the radiological views change frequently. In the Organ Doses Calculation Software application (ODS-60), the phantom model is similar in principle to the Alderson-Rando (A-R) phantom, but its sex, size and shape is modified according to a particular patient. Organ and effective doses are computed online (in a few seconds) using a method similar to the traditional dose planning systems used in radiotherapy. In this paper, the new ODS-60 software is presented in detail and its capabilities are demonstrated. Software performance was determined by comparing the results with those from independent methods. In the case of a reference man-sized male, the effective dose was about 7% larger than the effective dose given in another publication. In the case of a reference woman-sized female, the disagreement with the other method was greater (33%). Anatomical differences between the phantom models (ODS-60 and MC) were found to be the main reasons for these findings. This paper shows the advantage of using a patient size- and sex-adaptable phantom for patient dose determinations; the conversion coefficient from entrance surface dose-to-effective dose ratio between male (170 cm, 85 kg) and a female (160 cm, 43 kg) varies in the range 1.5-2.Keywords
This publication has 10 references indexed in Scilit:
- Organ Dose Determinations of X-Ray Examinations Using TL Detectors for Verification of Computed DosesRadiation Protection Dosimetry, 1996
- Electromagnetic pulse distortion in living tissueMedical & Biological Engineering & Computing, 1996
- Radiation-Induced Skin Injury after Percutaneous Transluminal Coronary AngioplastyActa Radiologica, 1996
- Radiation-induced temporary epilation after a neuroradiologically guided embolization procedure.Radiology, 1994
- Estimation of effective dose from dose–area product measurements for barium meals and barium enemasThe British Journal of Radiology, 1994
- Potential Biological Effects Following High X-ray Dose Interventional ProceduresJournal of Vascular and Interventional Radiology, 1994
- Assessment of Effective Dose in X Ray Imaging in View of the Proposed ICRP Risk FactorsRadiation Protection Dosimetry, 1992
- Dependence of the photon backscatter factor for water on source-to-phantom distance and irradiation field sizePhysics in Medicine & Biology, 1990
- Calculation of the Estimated Collective Effective Dose Equivalent (SE) Due to X-ray Diagnostic Examinations - Estimate of the SE in FinlandHealth Physics, 1987
- Conversion factor f for X-ray beam qualities, specified by peak tube potential and HVL valuePhysics in Medicine & Biology, 1987