Traceable Phosphorus Measurements by ICP-OES and HPLC for the Quantitation of DNA
- 10 January 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (4) , 1536-1541
- https://doi.org/10.1021/ac061463b
Abstract
Measurement of the phosphorus content of nucleotides and deoxyribonucleic acid (DNA) offers an approach to the quantitation of nucleic acids that is traceable to the SI. Such measurements can be an alternative to the commonly used spectroscopic tools that are not traceable. Phosphorus measurements of thymidine 5‘-monophosphate (TMP) and acid-digested plasmid and genomic DNA preparations were made using high-performance inductively coupled plasma optical emission spectroscopy (HP-ICP-OES) and high-performance liquid chromatography (HPLC) and compared for bias and uncertainty. A prerequisite for quality measurement is the purity of the materials. Quantitation with the two platforms was comparable for the TMP. However, the HPLC values had larger uncertainties and were all statistically different from the gravimetric values at the 95% confidence level. When using ICP-OES, the digestion of the nucleotide monophosphate can be eliminated, thus simplifying the procedure. The differences between the results obtained by using the two platforms, when measuring genomic or plasmid DNA, were dependent on the mass fraction of the digest. ICP-OES measurement of phosphorus provides a highly accurate quantitation for both nucleotide monophosphates and DNA with expanded uncertainties of less than 0.1%. Currently, ICP-OES requires a significant sample size restricting its usefulness for the quantitation of DNA but represents a valuable tool for certification of reference materials. HPLC requires smaller amounts of material to perform the analysis but is less useful for certification of reference materials because of lower accuracy and 10-fold higher expanded uncertainties.Keywords
This publication has 20 references indexed in Scilit:
- Use of Elemental Analysis To Determine Comparative Performance of Established DNA Quantification MethodsAnalytical Chemistry, 2006
- Quantitative determination of melphalan DNA adducts using HPLC—inductively coupled mass spectrometryJournal of Mass Spectrometry, 2006
- Traceability of Single-Element Calibration SolutionsAnalytical Chemistry, 2005
- A comparison of enzymatic digestion for the quantitation of an oligonucleotide by liquid chromatography–isotope dilution mass spectrometryJournal of Chromatography B, 2005
- Detection of metals in proteins by means of polyacrylamide gel electrophoresis and laser ablation‐inductively coupled plasma‐mass spectrometry: Application to seleniumElectrophoresis, 2003
- Determination of phosphorus in phosphorylated deoxyribonucleotides using capillary electrophoresis and high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cellJournal of Analytical Atomic Spectrometry, 2003
- Spotting and quantification of phosphoproteins purified by gel electrophoresis and laser ablation‐element mass spectrometry with phosphorus‐31 detectionElectrophoresis, 2003
- Thermochemistry of the biochemical reaction: { pyrophosphate(aq) + H2O(l) = 2 phosphate(aq)}The Journal of Chemical Thermodynamics, 2002
- An ICP-OES Method with 0.2 Expanded Uncertainties for the Characterization of LiAlO2Analytical Chemistry, 2000
- A Drift Correction ProcedureAnalytical Chemistry, 1998