Can coronary systolic-diastolic flow differences be predicted by left ventricular pressure or time-varying intramyocardial elastance?
- 1 March 1989
- journal article
- research article
- Published by Springer Nature in Basic Research in Cardiology
- Vol. 84 (2) , 149-159
- https://doi.org/10.1007/bf01907924
Abstract
In six isolated rabbit hearts perfused with a pressure source and Krebs-Henseleit as the perfusion medium, the effect of left ventricular pressure on coronary inflow in the maximally vasodilated bed was studied. This effect was determined from isovolumic beats, low afterloaded isobaric beats (afterload maintained at values below 10 mm Hg) and during cardiac arrest. For isovolumic beats end-diastolic left ventricular pressure was varied by means of an intraventricular balloon between 0–40 mm Hg and systolic left ventricular pressure varied between 90–130 mm Hg. In these ranges diastolic inflow decreased significantly 18±6% (mean±SD) with increasing pressure and systolic inflow could not be shown to depend on pressure (n=6). For isobaric beats, diastolic and systolic inflow remained at values similar to those found for the isovolumic beats (n=6). In the arrested heart inflow diminished 8±2% when the pressure in the left ventricle was increased from 0 to 40 mm Hg (n=3). We conclude that systolic coronary inflow is hardly affected by left ventricular pressure. Systolic inflow decreased by the same amount in the isovolumically and isobarically beating heart, when cardiac contractility was enhanced by epinephrine infusion. We suggest the results can be explained on the basis of the time-varying elastance concept: systolic elastance is the same for isovolumic and isobaric beats but depends on contractility. Models that relate coronary inflow impediment to left ventricular pressure should therefore be reevaluated.Keywords
This publication has 16 references indexed in Scilit:
- Relationship between myocardial oxygen consumption, coronary flow, and adenosine release in an improved isolated working heart preparation of guinea pigs.Circulation Research, 1983
- Diastolic-systolic coronary flow differences are caused by intramyocardial pump action in the anesthetized dog.Circulation Research, 1981
- Transmural distribution of intrinsic and transmitted left ventricular diastolic intramyocardial pressure in dogsCardiovascular Research, 1978
- Factors which affect the diastolic pressure-volume curve.Circulation Research, 1978
- Transmural distribution of myocardial blood flow during systole in the awake dog.Circulation Research, 1976
- Intramyocardial pressure: Effect of preload on transmural distribution of systolic coronary blood flowThe American Journal of Cardiology, 1975
- Inhibition of coronary blood flow by a vascular waterfall mechanism.Circulation Research, 1975
- Effects of Myocardial Strains on Coronary Blood FlowCirculation Research, 1974
- Experimental Subendocardial Ischemia in Dogs with Normal Coronary ArteriesCirculation Research, 1972
- Effect of Cardiac Contraction on Coronary Blood FlowCirculation, 1957