Low-Energy Cardioversion of Spontaneous Atrial Fibrillation
- 1 July 1997
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 96 (1) , 253-259
- https://doi.org/10.1161/01.cir.96.1.253
Abstract
Background Recent studies have suggested that induced atrial fibrillation (AF) could be successfully terminated by using a two-catheter electrode system and low energy (Methods and Results Forty-two consecutive patients with spontaneous AF underwent low-energy electrical cardioversion. AF was chronic (≥1 month) with a mean duration of 9±19 months in 28 patients (group I) or paroxysmal with a history of recurrent attacks and a mean duration of the present episode of 7±16 days in 14 patients (group II). An underlying heart disease was present in 28 patients. A 3/3-ms biphasic shock was delivered between catheters positioned in the right atrium and the coronary sinus in 32 patients. In 10 patients, the left pulmonary artery branch was used. The catheters were connected to a custom external defibrillator. The shocks were synchronized to the R wave. Following a test shock of 60 V, the energy was increased in 40-V steps until a maximum of 400 V or restoration of sinus rhythm. Sinus rhythm was restored in 22 of the 28 patients (78%) of group I by using a mean leading-edge voltage of 297±57 V (mean energy, 3.3±1.3 J) and in 11 of 14 patients (78%) of group II by using a mean leading-edge voltage of 223±41 V (mean energy, 1.8±0.7 J). The energy required for terminating chronic AF was significantly ( P <.001) higher than that required for terminating paroxysmal AF. Among the other variables studied, the duration of AF significantly affected the successful voltage. Ventricular proarrhythmia occurred in 1 patient with atrial flutter due to an unsynchronized shock. Of the 22 patients of group I in whom sinus rhythm was restored, 14 (63%) remained in sinus rhythm with a mean follow-up of 9±3 months. Pain level showed a good correlation with increasing voltage. However, a marked interindividual variation was noted. Conclusions Atrial defibrillation using low energy between two intracardiac catheters with an electrical field between the right and left atria and the protocol used is feasible in patients with persistent spontaneous AF. The technique is safe provided synchronization to the R wave is achieved. A low recurrence rate of AF was seen in patients in whom sinus rhythm was restored.Keywords
This publication has 8 references indexed in Scilit:
- Efficacy and tolerability of transvenous low energy cardioversion of paroxysmal atrial fibrillation in humansJournal of the American College of Cardiology, 1995
- Is There Any Indication for an Intracardiac Defibrillator for the Treatment of Atrial Fibrillation?Journal of Cardiovascular Electrophysiology, 1994
- Initial Experience with Intracardiac Atrial Defibrillation in Patients with Chronic Atrial FibrillationPacing and Clinical Electrophysiology, 1994
- Antiarrhythmic drug therapy and cardiac mortality in atrial fibrillationJournal of the American College of Cardiology, 1992
- Effects of Transcatheter Cardioversion on Chronic Lone Atrial FibrillationPacing and Clinical Electrophysiology, 1991
- Efficacy and safety of quinidine therapy for maintenance of sinus rhythm after cardioversion. A meta-analysis of randomized control trials.Circulation, 1990
- High energy transcatheter cardioversion of chronic atrial fibrillationJournal of the American College of Cardiology, 1988
- Epidemiologic Features of Chronic Atrial FibrillationNew England Journal of Medicine, 1982