Coronary Arteries: Diagnostic Performance of 16- versus 64-Section Spiral CT Compared with Invasive Coronary Angiography—Meta-Analysis
Top Cited Papers
- 1 December 2007
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 245 (3) , 720-731
- https://doi.org/10.1148/radiol.2453061899
Abstract
To perform a meta-analysis to compare the diagnostic performance of 16- versus 64-section computed tomography (CT) for the diagnosis of coronary artery disease (CAD). The MEDLINE database was searched for relevant original articles. Criteria for inclusion of articles were (a) use of multisection spiral CT as a diagnostic test for obstructive CAD, (b) use of the newer generation of multisection spiral CT (16 or 64 section) scanners, and (c) use of coronary angiography as the reference standard for diagnosing obstructive CAD (>50% diameter stenosis was selected as the cutoff criterion for diagnosis of CAD). After data extraction, the analysis was performed according to a random-effects model. Between-study statistical heterogeneity also was assessed by using Cochran Q chi(2) tests. Of 328 identified relevant articles, 37 fulfilled all inclusion criteria, with data available for a patient-based analysis in 28. The patient-based analysis included pooled data from 16 studies, corresponding to 1292 patients who underwent 16-section spiral CT, and from 12 studies, corresponding to 695 patients who underwent 64-section spiral CT. Respectively, the results for 16-section CT versus 64-section CT were 95% (95% confidence interval [CI]: 93%, 96%) versus 97% (95% CI: 95%, 98%) for sensitivity (P = .03), 69% (95% CI: 66%, 73%) versus 90% (95% CI: 86%, 93%) for specificity (P < .001), 79% (95% CI: 76%, 82%) versus 93% (95% CI: 91%, 96%) for positive predictive value (PPV) (P < .001), 92% (95% CI: 88%, 94%) versus 96% (95% CI: 92%, 98%) for negative predictive value (P < .001), and 72.05 (95% CI: 31.35, 165.56) versus 181.82 (95% CI: 88.70, 372.71) for diagnostic odds ratio (P = .1). Sixty-four-section spiral CT has significantly higher specificity and PPV on a per-patient basis compared with 16-section CT for the detection of greater than 50% stenosis of coronary arteries. http://radiology.rsnajnls.org/cgi/content/full/2453061899/DC1.Keywords
This publication has 46 references indexed in Scilit:
- Heart Disease and Stroke Statistics—2006 UpdateCirculation, 2006
- Predictive Value of 16-Slice Multidetector Spiral Computed Tomography to Detect Significant Obstructive Coronary Artery Disease in Patients at High Risk for Coronary Artery DiseaseCirculation, 2004
- Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: Initial clinical resultsJournal of the American College of Cardiology, 2004
- Radial versus femoral approach for percutaneous coronary diagnostic and interventional proceduresJournal of the American College of Cardiology, 2004
- Accuracy of thin-slice computed tomography in the detection of coronary stenosesEuropean Heart Journal, 2004
- The diagnostic odds ratio: a single indicator of test performanceJournal of Clinical Epidemiology, 2003
- Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed TomographyCirculation, 2002
- Exploring sources of heterogeneity in systematic reviews of diagnostic testsStatistics in Medicine, 2002
- Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test dataStatistics in Medicine, 2002
- Combining independent studies of a diagnostic test into a summary roc curve: Data‐analytic approaches and some additional considerationsStatistics in Medicine, 1993