Heliox improves hemodynamics in mechanically ventilated patients with chronic obstructive pulmonary disease with systolic pressure variations
- 1 May 2005
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 33 (5) , 968-973
- https://doi.org/10.1097/01.ccm.0000163403.42842.fe
Abstract
To test the hypothesis that, compared with air-oxygen, heliox would improve cardiac performance in mechanically ventilated patients with severe chronic obstructive pulmonary disease and systolic pressure variations >15 mm Hg and to determine clinical variables associated with favorable hemodynamic responses to heliox. A prospective interventional study. Medical and respiratory intensive care units at a university-affiliated tertiary medical center. Twenty-five consecutive mechanically ventilated patients with severe chronic obstructive pulmonary disease and acute respiratory failure who had systolic pressure variations >15 mm Hg. Respiratory and hemodynamic measurements were taken at the following time with the same ventilator setting: a) baseline; b) after 30 mins with heliox; and c) 30 mins after return to air-oxygen. Heliox ventilation decreased intrinsic positive end-expiratory pressure (air-oxygen vs. heliox [mean ± sd] 13 ± 4 cm H2O vs. 5 ± 2 cm H2O, p < .05), trapped lung volume (air-oxygen vs. heliox 362 ± 67 mL vs. 174 ± 86 mL, p < .05), and respiratory changes in systolic pressure variations (ΔPP) (air-oxygen vs. heliox 29 ± 5% vs. 13 ± 7%, p < .05). In the ten patients with pulmonary arterial catheters, heliox decreased mean pulmonary arterial pressure, right atrial pressure, and pulmonary arterial occlusion pressure and increased cardiac index. Preheliox ΔPP correlated with the magnitude of reduction in intrinsic positive end-expiratory pressure during heliox ventilation. Age, preheliox Paco2, and ratio of forced expiratory volume at first second to forced vital capacity correlated inversely, whereas preheliox ΔPP correlated positively with increases in cardiac index. Heliox may be a useful adjunct therapy in patients with severe chronic obstructive pulmonary disease during acute respiratory failure who have persistent intrinsic positive end-expiratory pressure-induced hemodynamic changes despite ventilator management.Keywords
This publication has 24 references indexed in Scilit:
- Comparative effects of helium-oxygen and external positive end-expiratory pressure on respiratory mechanics, gas exchange, and ventilation-perfusion relationships in mechanically ventilated patients with chronic obstructive pulmonary diseaseIntensive Care Medicine, 2003
- Helium/oxygen mixture reduces the work of breathing at the end of the weaning process in patients with severe chronic obstructive pulmonary diseaseCritical Care Medicine, 2003
- Helium-oxygen versus air-oxygen noninvasive pressure support in decompensated chronic obstructive disease: A prospective, multicenter study*Critical Care Medicine, 2003
- Intrinsic PEEP and cardiopulmonary interaction in patients with COPD and acute ventilatory failureEuropean Respiratory Journal, 1996
- Theoretical validation of the respiratory benefits of helium-oxygen mixturesRespiration Physiology, 1995
- Heliox in Respiratory Failure from Obstructive Lung DiseaseNew England Journal of Medicine, 1995
- A bedside index assessing the reliability of pulmonary artery occlusion pressure measurements during mechanical ventilation with positive end-expiratory pressureJournal of Critical Care, 1992
- Reevaluation of Hemodynamic Consequences of Positive Pressure VentilationAnesthesiology, 1990
- A re-evaluation of the hemodynamic consequences of intermittent positive pressure ventilationCritical Care Medicine, 1983
- Hemodynamic Effects of Intermittent Positive Pressure RespirationAnesthesiology, 1966