Horizontal semi‐dry electroblotting for the detection of the low density lipoprotein receptor in solubilized liver membranes
- 1 January 1993
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 14 (1) , 794-797
- https://doi.org/10.1002/elps.11501401124
Abstract
A high efficiency transfer of the low density lipoprotein (LDL) receptor proteins from polyacrylamide slab gel onto immobilizing nitrocellulose membranes using the horizontal semi-dry electrophoretic system is described. The transfer of the LDL receptors from solubilized rat liver microsomes was performed between two graphite plate electrodes in a continuous buffer system containing methanol and sodium dodecyl sulfate. The protein transfer was achieved in only 150 min at a constant current of 0.8 mA/cm2 at room temperature with very low Joule heat development. The homogeneous electric field yield between the two electrode plates produced a satisfactory transfer of the LDL-receptor protein band in spite of its high molecular weight, and only few protein traces remained in the polyacrylamide gel after blotting. This improved method allows a rapid and quantitative transfer of the LDL receptors without protein denaturation, since the specific binding activity of the blotted receptor is retained as demonstrated by ligand-blotting and immuno-blotting.Keywords
This publication has 25 references indexed in Scilit:
- Hormonal regulation of low‐density lipoprotein (LDL) receptor activity in human hepatoma Hep G2 cellsEuropean Journal of Biochemistry, 1988
- Comparison of semi‐dry and conventional tank‐buffer electrotransfer of proteins from polyacrylamide gels to nitrocellulose membranesElectrophoresis, 1987
- Binding of low-density lipoprotein and chylomicron remnants to the hepatic low-density lipoprotein receptor of dogs, rats and rabbits demonstrated by ligand blotting. Failure to detect a distinct chylomicron-remnant-binding protein by ligand blottingEuropean Journal of Biochemistry, 1986
- [8] Single vertical spin density gradient ultracentrifugationPublished by Elsevier ,1986
- Protein blottingElectrophoresis, 1986
- Electroblotting of multiple gels: a simple apparatus without buffer tank for rapid transfer of proteins from polycrylamide to nitrocelluloseJournal of Biochemical and Biophysical Methods, 1984
- “Western Blotting”: Electrophoretic transfer of proteins from sodium dodecyl sulfate-polyacrylamide gels to unmodified nitrocellulose and radiographic detection with antibody and radioiodinated protein AAnalytical Biochemistry, 1981
- Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets: procedure and some applications.Proceedings of the National Academy of Sciences, 1979
- X-ray intensifying screens greatly enhance the detection by autoradiography of the radioactive isotopes 32P and 125IAnalytical Biochemistry, 1978
- Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4Nature, 1970