Abstract
A digital computer design program has been used to evaluate the effects of temperature rise on induction motor performance. The limiting performance guarantees are identified for 40 C (degrees centigrade) rise and 60 C rise machines. Class F and Class H temperature rises appear to require changes in machine geometry if these insulations are to be most effectively used in general-purpose induction motors.Keywords
This publication has 2 references indexed in Scilit:
- Optimum Machine Design by Digital ComputerTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1959