Mechanics of the Knee
- 1 January 1985
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 56 (sup216) , 1-42
- https://doi.org/10.3109/17453678509154159
Abstract
The load moment of force about the knee joint during machine milking and when lifting a 12.8 kg box was quantified using a computerized static sagittal plane body model. Surface electromyography of quadriceps and hamstrings muscles was normalized and expressed as a percentage of an isometric maximum voluntary test contraction. Working with straight knees and the trunk flexed forwards induced extending knee load moments of maximum 55 Nm. Lifting the box with flexed knees gave flexing moments of 50 Nm at the beginning of the lift, irrespective of whether the burden was between or in front of the feet. During machine milking, a level difference between operator and cow of 0.70 m − 1.0 m significantly lowered the knee extending moments. To quantify the force magnitudes acting in the tibio-femoral and patello-femoral joints, a local biomechanical model of the knee was developed using a combination of cadaver knee dissections and lateral knee radiographs of healthy subjects. The moment arm of the knee extensor was significantly shorter for women than for men, which resulted in higher knee joint forces in women if the same moment was produced. A diagram for quantifying patellar forces was worked out. The force magnitudes given by the knee joint biomechanical model correlated well with experimentally forces measured by others. During the parallel squat in powerlifting, the maximum flexing knee load moment was estimated to 335 − 550 Nm when carrying a 382.5 kg burden and the in vivo force of a complete quadriceps tendon-muscle rupture to between 10,900 and 18,300 N. During isokinetic knee extension, the tibio-femoral compressive force reached peak magnitudes of 9 times body weight and the anteroposterior shear force was close to 1 body weight at knee angles straighter than 60 degrees, indicating that high forces stress the anterior cruciate ligament. A proximal resistance pad position decreased the shear force considerably, and this position is recommended in early rehabilitation after anterior cruciate ligament repairs or reconstructions. The methods presented quantify muscle activity, sagittal knee joint moments and forces, enabling assessments to be made of different work postures, training exercises and joint derangements.Keywords
This publication has 112 references indexed in Scilit:
- Quadriceps Tendon Ruptures in UremiaPublished by Wolters Kluwer Health ,1985
- Forces in the knee joint whilst rising from a seated positionJournal of Biomedical Engineering, 1984
- In-Vitro of Measurement of Static Pressure Distribution in Synovial Joints—Part I: Tibial Surface of the KneeJournal of Biomechanical Engineering, 1983
- In-Vitro Measurement of Static Pressure Distribution in Synovial Joints—Part II: Retropatellar SurfaceJournal of Biomechanical Engineering, 1983
- Impulse and Moment of Impulse in the Leg Joints by Impact From KickingJournal of Biomechanical Engineering, 1983
- Strength of Plantar Flexion and Function After Resection of Various Parts of the Triceps Surae MuscleActa Orthopaedica, 1979
- Isometric Knee Extension Strength as a Function of Joint Angle, Muscle Length and Motor Unit ActivityActa Orthopaedica, 1972
- Knee Extension:Measurement of the Isometric Force in Different Positions of the Knee-JointActa Orthopaedica, 1969
- Degenerative changes in the knee after meniscectomy.BMJ, 1968
- Bilateral Rupture of Rectus Femoris Tendons in Chronic NephritisBMJ, 1957