Abstract
A method was set up for single-photon emission tomographic (SPET) quantification of radioactivity concentration in small anatomical structures. The method is based on the theoretical model proposed by Kessler et al. (J. Comput Assist Tomogr 1984; 8: 514–522) describing the effects of spatial resolution (partial volume effect and spillover) on the quantification of radioactivity concentration in small spherical objects. The model was validated here in SPET, by phantom experimental measurements, in relation to object size and source/background contrast. Good agreement was found between model-predicted and SPET-measured radioactivity concentration ratios in hot spots in hot background experiments. Accuracy of the method was assessed for comparison of model-corrected and true radioactivity concentration ratios and was found to be within 8.5% over the full range of object size (9.4–36.5 mm). The good agreement found indicates that the model can be used to correct for partial volume effect and spillover in specific clinical situations, when the anatomical structure under study can be approximated by a sphere of known size (e.g. neuroreceptor and tumour studies). The method was applied to a representative SPET monoclonal antibody patient study for the quantification of radioactivity concentration in ocular melanoma.Keywords
This publication has 23 references indexed in Scilit:
- Graphical, Kinetic, and Equilibrium Analyses of in vivo [123I]β-CIT Binding to Dopamine Transporters in Healthy Human SubjectsJournal of Cerebral Blood Flow & Metabolism, 1994
- Evaluation of the factors affecting the accuracy and precision of a technique for quantification of volume and activity in SPECTNuclear Medicine Communications, 1994
- Pre-targeted immunodetection in glioma patients: tumour localization and single-photon emission tomography imaging of [99mTc]PnAO-biotinEuropean Journal of Nuclear Medicine and Molecular Imaging, 1994
- CERASPECT: a brain-dedicated SPECT system. Performance evaluation and comparison with the rotating gamma cameraPhysics in Medicine & Biology, 1993
- Measurement of Radiotracer Concentration in Brain Gray Matter Using Positron Emission Tomography: MRI-Based Correction for Partial Volume EffectsJournal of Cerebral Blood Flow & Metabolism, 1992
- Quantitation of the human basal ganglia with positron emission tomography: a phantom study of the effect of contrast and axial positioningIEEE Transactions on Medical Imaging, 1991
- Regional Correction of Positron Emission Tomography Data for the Effects of Cerebral AtrophyJournal of Cerebral Blood Flow & Metabolism, 1988
- Analysis of Emission Tomographic Scan Data: Limitations Imposed by Resolution and BackgroundJournal of Computer Assisted Tomography, 1984
- Quantitation in Positron Emission Computed Tomography: 5. Physical–Anatomical EffectsJournal of Computer Assisted Tomography, 1981
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1979