A review of computational fluid dynamics analysis of blood pumps
- 1 August 2009
- journal article
- review article
- Published by Cambridge University Press (CUP) in European Journal of Applied Mathematics
- Vol. 20 (4) , 363-397
- https://doi.org/10.1017/s0956792509007839
Abstract
Ventricular assist devices (VADs) provide long- and short-term support to chronically ill heart disease patients; these devices are expected to match the remarkable functionality of the natural heart, which makes their design a very challenging task. Blood pumps, the principal component of the VADs, must operate over a wide range of flow rates and pressure heads and minimise the damage to blood cells in the process. They should also be small to allow easy implantation in both children and adults. Mathematical methods and computational fluid dynamics (CFD) have recently emerged as powerful design tools in this context; a review of the recent advances in the field is presented here. This review focusses on the CFD-based design strategies applied to blood flow in blood pumps and other blood-handling devices. Both simulation methods for blood flow and blood damage models are reviewed. The literature is put into context with a discussion of the chronological development in the field. The review is illustrated with specific examples drawn from our group's Galerkin/least squares (GLS) finite-element simulations of the basic Newtonian flow problem for the continuous-flow centrifugal GYRO blood pump. The GLS formulation is outlined, and modifications to include models that better represent blood rheology are shown. Haemocompatibility analysis of the pump is reviewed in the context of haemolysis estimations based on different blood damage models. Our strain-based blood damage model that accounts for the viscoleasticity associated with the red blood cells is reviewed in detail. The viability of design improvement based on trial and error and complete simulation-based design optimisation schemes are also discussed.Keywords
This publication has 117 references indexed in Scilit:
- A new microstructure-based constitutive model for human bloodJournal of Non-Newtonian Fluid Mechanics, 2006
- Four-field Galerkin/least-squares formulation for viscoelastic fluidsJournal of Non-Newtonian Fluid Mechanics, 2006
- Flow of viscoelastic fluids past a cylinder at high Weissenberg number: Stabilized simulations using matrix logarithmsJournal of Non-Newtonian Fluid Mechanics, 2005
- Shear-slip Mesh Update Method: Implementation and ApplicationsComputer Methods in Biomechanics and Biomedical Engineering, 2003
- Free surface flows of polymer solutions with models based on the conformation tensorJournal of Non-Newtonian Fluid Mechanics, 2002
- Can Rotary Blood Pumps Replace Pulsatile Devices?Artificial Organs, 2001
- The History of Continuous‐Flow Blood PumpsArtificial Organs, 2000
- Mixed finite element methods for viscoelastic flow analysis: a reviewJournal of Non-Newtonian Fluid Mechanics, 1998
- Equation of change for ellipsoidal drops in viscous flowJournal of Non-Newtonian Fluid Mechanics, 1998
- Conformation tensor rheological modelsJournal of Non-Newtonian Fluid Mechanics, 1987