Efficient separation and analysis of peroxisomal membrane proteins using free‐flow isoelectric focusing
- 17 June 2004
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 25 (12) , 1735-1747
- https://doi.org/10.1002/elps.200305834
Abstract
We have elaborated a protocol for the fractionation of both hydrophilic and hydrophobic proteins using as a model the matrix and membrane compartments of highly purified rat liver peroxisomes because of their distinct proteomes and characteristic composition with a high quota of basic proteins. To keep highly hydrophobic proteins in solution, an urea/thiourea/detergent mixture, as used in traditional gel‐based isoelectric focusing (IEF), was added to the electrophoresis buffer. Electrophoresis was conducted in the ProTeam free‐flow electrophoresis (FFE) apparatus of TECAN separating proteins into 96 fractions on a pH 3–12 gradient. Consecutive sodium dodecyl sulfate‐polyacrylamide gel electrophoresis (SDS‐PAGE) analysis demonstrated that both matrix and the integral membrane proteins of peroxisomes could be successfully fractionated and then identified by mass spectrometry. This is documented by the detection of PMP22, which is the most hydrophobic and basic protein of the peroxisomal membrane with a pI > 10. The identification of 96 prominent spots corresponding to polypeptides with different physical and chemical properties, e.g., the most abundant integral membrane polypeptides of peroxisomes and specific ones of the mitochondrial and microsomal membrane, reflects the fractionation potential of free‐flow (FF)‐IEF, accentuating its value in proteomic research as an alternative perhaps superior to gel‐based IEF.Keywords
This publication has 53 references indexed in Scilit:
- Improved proteome analysis of Saccharomyces cerevisiae mitochondria by free‐flow electrophoresisProteomics, 2003
- Comparison of one-dimensional and two-dimensional gel electrophoresis as a separation tool for proteomic analysis of rat liver microsomes: Cytochromes P450 and other membrane proteinsProteomics, 2002
- Recent developments in preparative free flow isoelectric focusingElectrophoresis, 1998
- Isolation of peroxisome subpopulations from rat liver by means of immune free‐flow electrophoresisElectrophoresis, 1998
- Cytochrome P-450 2E1 in Rat Liver Peroxisomes: Downregulation by Ischemia/Reperfusion-Induced Oxidative StressFree Radical Biology & Medicine, 1997
- Free flow‐isoelectric focusing of human cellular lysates as sample preparation for protein analysisElectrophoresis, 1995
- BIOCHEMISTRY OF PEROXISOMESAnnual Review of Biochemistry, 1992
- β‐oxidation of polyunsaturated fatty acids in peroxisomes Subcellular distribution of Δ3,Δ2‐enoyl‐CoA isomerase activity in rat liverFEBS Letters, 1987
- Free-Flow Electrophoresis III. An Analytical Version for a Rapid, Quantitative Determination of Electrophoretic ParametersHoppe-Seyler´s Zeitschrift Für Physiologische Chemie, 1977
- Eine Neuentwicklung der trägerfreien kontinuierlichen Elektrophorese. Zur Trennung hochmolekularer und grobdisperser TeilchenHoppe-Seyler´s Zeitschrift Für Physiologische Chemie, 1964