Fritless Packed Columns for Capillary Electrochromatography: Separation of Uncharged Compounds on Hydrophobic Hydrogels
- 1 September 1996
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (17) , 2753-2757
- https://doi.org/10.1021/ac9601775
Abstract
A novel column is described that does not require frits to keep packing material within a capillary. A continuous bed is prepared in situ in aqueous solution by radical copolymerization of N-isopropylacrylamide and 2-acrylamido-2-methylpropanesulfonic acid (the resultant gel is denoted poly(AMPS-co-IPAAm). N,N‘-Methylenebisacrylamide is used for cross-linking. On the application of an electrical field, electroosmotic flow (EOF) is developed in the bed along the capillary, where fluid propulsion would be otherwise difficult to achieve. The resultant EOF transports neutral compounds through the column without forcing the gel out of the capillary. Examination of the fluid motion in the continuous bed using a video microscope system and an image processor shows a relatively flat flow profile of EOF. The bed functions as the stationary phase for reversed-phase capillary electrochromatography (CEC). This new approach is an alternative to packed capillary columns which have been used previously in CEC. A high efficiency is obtained for a steroid which is separated on a 4.0% total monomer concentration (T), 10.0% degree of cross-linking (C), and 10.0% mole fraction of AMPS in the total monomer (S), poly(AMPS-co-IPAAm) column. A mixture of polyaromatic hydrocarbons is separated on a 6.9% T, 5.8% C, and 5.5% S poly(AMPS-co-IPAAm) column. The capacity factor of benzo[a]pyrene increases from 0.63 to 1.91 as the acetonitrile content in a Tris−boric acid buffer is decreased from 45 to 30% (v/v). The run-to-run RSD of analyte migration time is less than 0.73%, and the day-to-day RSD is acceptable. Potential benefits of this approach are also mentioned.Keywords
This publication has 26 references indexed in Scilit:
- Capillary Electrochromatography-Electrospray Mass Spectrometry: A Microanalysis TechniqueAnalytical Chemistry, 1995
- Charged Polyacrylamide Gels for Capillary Electrochromatographic Separations of Uncharged, Low Molecular Weight CompoundsAnalytical Chemistry, 1995
- Enantiomer Separation by Electrochromatography in Open Tubular Columns Coated with Chirasil-DexJournal of Liquid Chromatography, 1993
- Continuous beds: high-resolving, cost-effective chromatographic matricesNature, 1992
- Enantiomer separation by electrochromatography on capillaries coated with chirasil‐dex. Dedicated to Professor Ernst Bayer on the occasion of his 65th birthdayJournal of High Resolution Chromatography, 1992
- Phase Separation in Gelling Silica–Organic Polymer Solution: Systems Containing Poly(sodium styrenesulfonate)Journal of the American Ceramic Society, 1991
- Open-tubular liquid chromatography with surfactant-enhanced electroosmotic flowAnalytical Chemistry, 1990
- Chromatographic behavior in electrochromatographyAnalytical Chemistry, 1988
- Thermal lens spectrophotometry using a tunable infrared laser generated by a stimulated Raman effectAnalytical Chemistry, 1987
- Electroosmotic propulsion of eluent through silica-based chromatographic mediaAnalytical Chemistry, 1983