Echocardiographic assessment of left ventricular filling characteristics after mitral valve replacement with the St Jude medical prosthesis.
Open Access
- 1 April 1981
- Vol. 45 (4) , 365-368
- https://doi.org/10.1136/hrt.45.4.365
Abstract
The major cause of late mortality and morbidity after prosthetic valve replacement is thromboembolism. The nidus for initiation of thrombus formation has been blood metal interfaces, and a new valve--the St Jude prosthesis--has therefore been developed without any metal components. We have assessed echocardiographically in 27 patients the effects of this valve on left ventricular filling characteristics when inserted in the mitral position and compared the findings with those in patients having mitral valve replacement with Starr-Edwards or Björk-Shiley prostheses and with those in patients undergoing repair of the native mitral valve. Echocardiograms were recorded and digitised. Measurements were made of the peak rate of increase of dimension (dD/dt) and duration of rapid filling. Values for the St Jude valve were 13.2 +/- 3.4 cm/s and 160 +/- 40 ms, respectively. The peak rate of dD/dt increase was significantly greater than with either the Björk-Shiley valve or the Starr-Edwards valve and was comparable with findings in mitral valve repair. The duration of the rapid filling phase was not significantly different from control values but was less than that of the Starr-Edwards valve. This study indicates that the new St Jude medical valve is less obstructive than either the Björk-Shiley or Starr-Edwards prostheses. This together with its low thrombogenicity suggests that further trials of this new valve should be undertaken.Keywords
This publication has 16 references indexed in Scilit:
- Assessment of left ventricular function in secundum atrial septal defect by computer analysis of the M-mode echocardiogram.Circulation, 1979
- A new cardiac prosthesis: the St. Jude Medical cardiac valve: in vivo results.Circulation, 1979
- Anticoagulants and the Bjork-Shiley prosthesis. Experience of 390 patients.Heart, 1978
- Echocardiographic assessment of left ventricular filling after mitral valve surgery.Heart, 1977
- Measurement of peak rates of left ventricular wall movement in man. Comparison of echocardiography with angiography.Heart, 1975
- Ball valve prostheses: Current appraisal of late resultsThe American Journal of Cardiology, 1975
- Role of echocardiography and phonocardiography in diagnosis of mitral paraprosthetic regurgitation with Starr-Edwards prostheses.Heart, 1973
- Measurement of instantaneous left ventricular dimension and filling rate in man, using echocardiography.Heart, 1973
- A New Tilting Disc Valve ProsthesisScandinavian Journal of Thoracic and Cardiovascular Surgery, 1969
- A critical analysis of the status of prosthetic valves and homograftsProgress in Cardiovascular Diseases, 1968